P/N YRD226-MNL-0001 Rev J
Part of ASSA ABLOY
23
1-3/8"* - 2" thick doors:
L = 3-1/2" (88.8mm)
2" - 2-1/4" thick doors:
L = 3-3/4" (95.3mm)
*Requires addition of Thin Door Kit.
L
W = .2" (5.2mm)
W
T
Tailpiece
T = .098" (2.5mm)
1. To Remove cylinder:
A. Remove outside lock from door.
B. Remove rubber gasket.
C. Insert small flathead screwdriver under spring.
Gently lift spring. Note: Notch on top of cylinder
engages spring.
D. Remove cylinder by pulling outward.
Before installing cylinder, be sure tailpiece is correct
length (see below).
2. To install new cylinder:
A. Reverse previous steps for removing cylinder.
C
Replacing Cylinder
Resetting Lock to Factory Defaults
Reset
Button
Inside Lock
Please use this procedure only when network primary
controller is missing or otherwise inoperable.
When lock is reset to factory defaults all Entry Codes
(including the Master Entry Code*) are deleted and all
programming features are reset to original default
settings (see below).
1. Remove battery cover and batteries.
2. Remove inside lock to access reset button.
3. Reset button (see image at right) is located beside
cable adapter.
4. While pressing reset button reinstall batteries. Hold
reset button a minimum of 3 seconds then release.
5. Replace battery cover.
After reset, Master Entry Code creation is the only
option available and must be performed prior to any
other programming of the lock.