Page #21 background imageLoading...
Page #21 background image
Table 7. Proc_Cal_005: Lower Valve Output Threshold (Continued)
Action 2: SLOWLY Activate (Feather) Lower Control.
Action 3: WATCH for Attachment Movement. When it first starts to move slowly, HOLD control steady and.....
Press * One Time while holding the control.
Action 4: STOP activating the Lower Control. LOOK at the display.
Go to the Calibration Step below that matches your display.
If You See..... Result out of range
Repeat Calibration
Press * One Time
You Will See: Lower Valve Output
Press * at Creep
Return to Action 2. Perform Actions 2 through 4 again.
If You See..... Tilt Bk Valve Output
Press * at Creep
To Continue with Calibrations.....
Go to Action 3 of Proc_Cal_006.
To Quit and Save....
Step 1: Press or
Until You See: Tilt Bk Valve Output
Back 1 Level
Step 2: Press * One Time
You Will See: Calibrations
Back 1 Level
Perform Proc_Cal_003: Save and Exit.
8000 YRM 1134 Proc_Cal_005: Lower Valve Output Threshold
Confidential/Proprietary - Do Not Copy or Duplicate 15