P/N: C11746310 REV. AB June 2022
29
STEP 9: END STOP INSTALLATION
WARNING
IMPROPERLY INSTALLED TROLLEY STOPS (CLIPS ANGLES) CAN
RESULT IN LOSS OF BRIDGE WITH RESULTANT INJURY AND DAMAGE.
TO AVOID INJURY AND DAMAGE:
INSTALL END STOPS ON BOTH ENDS OF BEAMS TO PREVENT HOIST
TROLLEY FROM RUNNING OFF END OF BEAM.
BRIDGE BEAM
FLANGE WIDTH
A
TROLLEY STOP
ANGLE SIZE*
(4 REQ’D.)
B C D
3-3/8" 2" 3 x 3 x 3/8 1" 2" 4"
3-5/8" THRU 4" 2-1/4" 3-1/2 x 3 x 3/8 1" 3" 5"
4-5/8" THRU 5-1/4" 2-3/4" 4 x 3 x 3/8 1-1/2" 3" 5"
5-1/2" THRU 6-3/4" 3-1/2" 5 x 3 x 3/8 1-3/4" 3" 5"
7" THRU 7-5/8" 4" 6 x 3 x 3/8 1-3/4" 4" 6"