PERIODIC MAINTENANCE
TNV Tier 4 Service Manual
5-19
Periodic Maintenance Procedures
13. Open the fuel cock (Figure 5-14, (3)).
14. Prime the fuel system. See Priming the Fuel
System on page 4-24.
Be sure to perform priming. If air is mixed to the
fuel, seizure to the supply pump and the injector
may result.
15. Check for leaks.
Perform the following maintenance every 1000
hours of operation.
• Change coolant
• Adjust intake/exhaust valve clearance (if
required)
Scald Hazard!
• Never remove the radiator cap if
the engine is hot. Steam and hot
engine coolant will spurt out and
seriously burn you. Allow the
engine to cool down before you
attempt to remove the radiator
cap.
• Tighten the radiator cap securely after you
check the radiator. Steam can spurt out
during engine operation if the cap is loose.
• Always check the level of the engine coolant
by observing the reserve tank.
• Failure to comply will result in death or
serious injury.
Burn Hazard!
• Wait until the engine cools before
you drain the engine coolant. Hot
engine coolant may splash and
burn you.
• Failure to comply could result in death or
serious injury.
Every 1000 Hours of Operation