GENERATOR OPERATION
76
YDG Operation Manual
SHUTTING DOWN THE
GENERATOR
Follow these steps to shut down the engine:
1. Turn the generator main switch (Figure 6, (1))
off.
2. With the engine speed lever at the “RUN”
position, operate the engine without load for
about five minutes.
3. Turn the generator key switch (Figure 6, (2)) to
“OFF.
Figure 6
4. If the engine will not be used for six months or
longer, follow the additional instructions in Long
Term Storage on page 123.
CAUTION
For maximum engine life, Yanmar
recommends that when shutting the
engine down, you allow the engine to
run, without load, for five minutes. This
will allow the engine components that
operate at high temperatures, such as
the exhaust system, to cool slightly
before the engine itself is shut down.
0000008enYDG
CAUTION
Do not stop the engine suddenly. This
may cause the temperature to rise
abnormally.
0000167en
BATTERY CHARGE ONLY
DC12V 8.3A
AC120V/240V
AC120V 41.6 A
DC
BREAKER
AC
SW
20.8 A
20A
30A
STARTER SW
OFF
ON
STA RT
NEUTRAL BONDED TO FRAME
240V
120V
V
240
120
0
0
~
(
1
)
(
2
)
0002442A