9
This is an indicator to indicate which working mode the weighing
indicator is at, if it’s auto mode, then auto indicator will
be on.
STABLE INDICATOR
This is an indicator to indicate a stable weight is being
displayed.
TARE INDICATOR
This is an indicator to indicate tare function is in operation
and net weight value being displayed;
ZERO INDICATOR
This is an indicator to indicate a net zero weight status.
TIME INDICATOR
This is an indicator to indicate current time is being
displayed.
Note: at back of the indicator, there is a 15-pin control socket
for input or output control
Pin 1 to Pin 7 is for input description:
Pin 7 Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1
Discharge
Permitted
Charge
Permitted
Discharge Charge Stop Start Public
I6 I5 I4 I3 I2 I1
When any of the pin from 2 to 7 is short connected to pin 1,
it just gives indicator one kind of input, corresponding input
I indicator will be on;
Pin 8 to Pin 15 is for output description:
Pin 15 Pin 14 Pin 13 Pin 12 Pin 11 Pin 10 Pin 9 Pin 8
12V NOT OK OK Discharge Slow 2 Fast 2 Slow 1 Fast 1
O7 O6 O5 O4 O3 O2 O1
When indicator is at the process of one of the statement,
corresponding output O indicator will be on.
There is a connection between this 15-pin control socket and
relay box with a cable offered by the supplier, when O indicator
is on, corresponding relay will work.
4.Parameter Setting and Calibration
4.1 Parameter setting
3
There are three types of parameter to be set, they are:
[SET—0]: Parameter for check
[SET—1]: Parameter for configuration and function
3
Calibration head must be put on to set parameter for [set-1] and [set-2], or else,
parameter value can’t be saved;