5 Installation Procedure
YASKAWA ELECTRIC SIEP C730600 59A V1000 Option Modbus TCP/IP Technical Manual 17
10. On models CIMR-VBA0006 to BA0018, 2A0008 to 2A0069, and 4A0001 to 4A0038, reattach the
terminal cover.
Refer to Figure 1 3 and Figure 14 for drive models CIMR-VBA0006 to BA0018, 2A0008 to 2A0020,
and 4A0001 to 4A0011, which require routing the ground wire through the provided notch when reinstalling
the terminal cover.
Figure 13
Figure 13 Reattach the Terminal Cover
(Models CIMR-VBA0006 to BA0018; 2A0008 to 2A0069; 4A0001 to 4A0038)
Figure 14
Figure 14 Terminal Cover Ground Wire Notch
(Models CIMR-VBA0006 to BA0018; 2A0008 to 2A0020; 4A0001 to 4A0011)
11. Remove the option cover and pass the ground wire through the inside of the drive bottom cover and into the
through-hole for the ground wire at the front of the option.
Figure 15
Figure 15 Ground Wire Routing
V1000
Ground wire
routing notch
V1000
Option Cover
V1000