7-3 Registers
Command Registers (Read / Write)
REGISTER
FUNCTION
BIT
DATA
DESCRIPTION
(in hex)
NO. SET
001 Operational Signals 0 0 Stop
1
Run
1
0
Forward Run
1
Reverse Run
2
1
External Fault
3
1
Fault Reset
4
1
Multi-function Input 1 is selected (closed terminal S3)
5
1
Multi-function Input 2 is selected (closed terminal S4)
6
1
Multi-function Input 3 is selected (closed terminal S5)
7
1
Multi-function Input 4 is selected (closed terminal S6)
002 Frequency Reference Reference unit determined by n103 (1)
003
Not Supported
0
will return zeros
004
Not Supported
0
will return zeros
005
Not Supported
0
will return zeros
006
Not Supported
0
will return zeros
007
Not Supported
0
will return zeros
008
Not Supported
0
will return zeros
009
Multi-function Contact Output
0
1
Multi-function Output 1 (MA-MC) (2)
1
1
Multi-function Output 2 (M1-M2) (3)
2-15
Not Used
00A Not Supported will return zeros
00B-01F Not Supported will return zeros
Notes:
1. Frequency Reference unit (n103) default setting is ‘0’ (0.1Hz / 1).
2. Effective when n041 = 15.
3. Effective when n042 = 15.