APPENDIX 4 CONSTANTS LIST
87
Table A5 Constants List (Cont’d)
Constant
No.
Name
Initial
Setting
User
Setting
Constant
No.
Name
Initial
Setting
User
Setting
E1-01 Input voltage setting 200
*1 *2
F6-01 DO-08 output mode selection 0
E1-02 Motor capacity selection
*2 *3
F9-01
Input level of external fault from trans-
mission option
0
E1-03 Motor rated voltage
*2 *3
F9-02
External fault from transmission op-
tion
0
E1-04 Motor rated current
*2 *3 *4
F9-03
Operation at external fault input from
transmission option
1
E1-05 Number of motor poles
*2 *3
F9-04
Trace sampling cycle of transmission
option
0
E1-06 Motor max. speed
*2 *3
F9-05
Selection of torque reference from
transmission option
1
E1-07 Motor base speed
*2 *3
F9-06
Operation selection at BUS error
detection
1
E1-08 Motor min. speed
*2 *3
H1-01 Multi-function input (terminal 3-11) 24
E1-09 Motor armature resistance
*2 *3
H1-02 Multi-function input (terminal 4-11) 14
E1-10 Motor d-axis inductance
*2 *3
H1-03 Multi-function input (terminal 5-11) 3 (0)
*5
E1-11 Motor q-axis inductance
*2 *3
H1-04 Multi-function input (terminal 6-11) 4 (3)
*5
E1-13 Induced voltage
*2 *3
H1-05 Multi-function input (terminal 7-11) 6 (4)
*5
E1-14
Variable torque/constant torque selec-
tion
0
*2
H1-06 Multi-function input (terminal 8-11) 8 (6)
*5
E1-15 Motor mechanical loss 0.0
*2
H2-01 Multi-function input (terminal 9-10) 0
E1-16 Motor wiring resistance 1.0
*2
H2-02 Multi-function input (terminal 25-27) 1
F1-01 PG constants 1024 H2-03 Multi-function input (terminal 26-27) 2
F1-02
Operation selection at PG open-circuit
(PGO) detection
1 H3-01 Signal level selection (terminal 13) 0
F1-03
Operation selection at overspeed (OS)
detection
1 H3-02 Gain (terminal 13) 100.0
F1-04
Operation selection at speed deviation
(DEV) detection
3 H3-03 Bias (terminal 13) 0.0
F1-05 PG rotation direction 1 H3-04 Signal level selection (terminal 16) 0
F1-08 Overspeed (OS) detection level 115 H3-05
Multi-function analog input (terminal
16)
00
F1-09 Overspeed (OS) detection delay time 0.0 H3-06 Gain (terminal 16) 100.0
F1-10 Speed deviation (DEV) detection level 10 H3-07 Bias (terminal 16) 0.0
F1-11
Speed deviation (DEV) detection
delay time
0.5 H3-08 Signal level selection (terminal 14) 2
F1-13
PGopen-circuit(PGO)detectiondelay
time
3.0 H3-09
Multi-function analog input (terminal
14)
1F
F2-01 AI-14B input function selection 0 H3-10 Gain (terminal 14) 100.0
F3-01
DI-08, DI-16H2 speed reference set-
ting selection
0 H3-11 Bias (terminal 14) 0.0
F4-01 AO-08, 12CH1 output item selection 5 H3-12 Analog input filter time 0.00
F4-02 AO-08, 12CH1 output gain 1.0 H4-01 Monitor selection (terminal 21-22) 5
F4-03 AO-08, 12CH1 output bias 0.0 H4-02 Gain (terminal 21-22) 1.0
F4-04 AO-08, 12CH2 output item selection 3 H4-03 Bias (terminal 21-22) 0.0
F4-05 AO-08, 12CH2 output gain 1.0 H4-04 Monitor selection (terminal 23-22) 3
F4-06 AO-08, 12CH2 output bias 0.0 H4-05 Gain (terminal 23-22) 1.0
F5-01 DO-02 CH1 output selection 0 H4-06 Bias (terminal 23-22) 0.0
F5-02 DO-02 CH2 output selection 1 H4-07 Analog output signal level selection 1
*1 Set value for 200V class. For 400V class, the value is twice as that of 200V class.
*2 Not initialized.
*3 Initial setting differs depending on motor capacity.
*4 0.01A for models of 7.5 kW or below.
*5 Initial settings in the parentheses are values obtained at 3-wire initialization.