EasyManuals Logo

YOKOGAWA DPharp EJA110E User Manual

YOKOGAWA DPharp EJA110E
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
<7. Errors and Countermeasures>
55
IM 01C25A01-01E
7. Errors and Countermeasures
NOTE
Table 7.1 Alarm Message Summary (Except EJX910A and EJX930A)
Indicator Cause
Output Operation
during Error
Countermeasure
None
AL. 01
CAP. ERR
AL. 02
AMP. ERR
AL. 10
PRESS necessary.
AL. 11
ST. PRSS
AL. 12
CAP. TMP
AL. 13
AMP. TMP
AL. 30
RANGE
Output is outside upper or lower range
AL. 31
SP. RNG range. output.
AL. 35 *
1
P. HI
AL. 36 *
1
P. LO
AL. 37 *
1
SP. HI
AL. 38 *
1
SP. LO
AL. 39 *
1
TMP. HI
AL. 40 *
1
TMP. LO
AL. 50
P. LRV range. occurred. needed.
AL. 51
P. URV
AL. 52
P. SPN
AL. 53
P. ADJ
AL. 54
SP. RNG needed.
AL. 55
SP. ADJ
AL. 60
SC. CFG
AL. 79
OV. DISP