IM 01F06A00-01E
Model DY
Vortex Flowmeter
(Integral Type, Remote Type)
Model DYA
Vortex Flow Converter
(Remote Type)
IM 01F06A00-01EN
13th Edition

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DY100 and is the answer not in the manual?

YOKOGAWA DY100 Specifications

General IconGeneral
ModelDY100
CategoryMeasuring Instruments
ManufacturerYokogawa
Power Supply100 to 240 VAC, 50/60 Hz or 24 VDC
MountingPanel Mount
Input SignalDC Voltage, DC Current, Thermocouple, RTD
DisplayLED
Accuracy±0.1% of reading ±1 digit
Dimensions96 x 48 x 100 mm
Digits5

Summary

INTRODUCTION

Notices Regarding Safety and Modification

Safety precautions and consequences of improper use or modification are detailed.

1. HANDLING PRECAUTIONS

Precautions Regarding Transportation and Storage Location

Guidelines for safe transportation and storage to prevent damage and deterioration.

2. INSTALLATION

Precautions Regarding Installation Locations

Detailed precautions for installation locations, covering temperature, atmosphere, shock, and piping.

2.6 Installing the Vortex Flow meter

3. WIRING

Wiring Precautions

Essential precautions to follow during wiring, including temperature limits and cable handling.

3.8 Grounding

4. BASIC OPERATING PROCEDURES

4.4 Setting Mode

Method of Parameter Setting

Detailed methods for setting parameters, including inputting numeric data and selecting items.

4.5 Operation for the BRAIN Terminal (BT200)

Setting Parameters

Method for setting parameters using the BT200 terminal, including changing flow span and pulse output.

4.6 Operation via HART configu ration tool

Self-diagnostic

How to perform and interpret self-diagnostics using the HART Configuration Tool.

5. PARAMETER SETUP

Item H: Adjust.

Parameters for instrument adjustment, including 4mA/20mA trimming, Reynolds adjustment, and flow adjustment.

5.4 Parameter Description

Item B: Easy Setting

Detailed explanation of key parameters for easy setup, including flow span, damping, and contact output types.

6. OPERATION

Adjustment

Procedures for adjusting the instrument, including zero adjustment and span adjustment.

Setting of Write Protect Switch

Methods for setting the write protect switch to prevent parameter overwriting.

7.5 Vortex Shedder Removal

7.6 Flow Calculation

Flow Calculation

Equations for calculating flowrate in engineering units, percentage, totalized value, and pulse output.

8. TROUBLESHOOTING

Flow

Troubleshooting guide for large flowmeter errors, fluctuating readings, and zero indication issues.

8.2 Flow (Only for MV)

9. GENERAL DESCRIPTION

Standard Specifications

Details on fluid type, accuracy, operating conditions, materials, and electrical parameters.

Option Multi-Variable (Build in Temperature Sensor) Type (MV)(*1)

Specifics of the multi-variable option, detailing function, fluid types, accuracy, and calculation methods.

Option Specifications (For Explosion Protected Type)

Specifications for explosion-protected types, covering ATEX, FM, CSA, and TIIS certifications.

Sizing

Guidelines for sizing the flowmeter based on minimum velocity, flow velocity ranges, and accuracy.

10. EXPLOSION PROTECTED TYPE INSTRUMENT

CENELEC ATEX (KEMA)

Technical data for CENELEC ATEX certified instruments, covering explosion proof and intrinsically safe types.

FM

Technical data, wiring, operation, maintenance, and installation diagrams for FM certified instruments.

SAA

Technical data, installation, operation, maintenance, and diagrams for SAA certified instruments.

CSA

Technical data, wiring, operation, maintenance, and installation diagrams for CSA certified instruments.

TIIS

Technical data and specifications for TIIS certified explosion protected type instruments.

Installation of Flameproof Apparatus

Installation Area

Guidelines for installing flameproof apparatus in hazardous areas (Zone 1, 2) and restrictions for Zone 0.

External Wiring for Flameproof Apparatus

Cable Wiring

Procedures for cable wiring, including cable glands, grounding, and using specified cables and protective pipes.

Maintenance of Flameproof Apparatus

Maintenance servicing with the power on.

Precautions for maintenance with power on, emphasizing gas detection and visual inspection.

Repair

Steps for repairing flameproof apparatus, including electrical/mechanical repairs and contacting the manufacturer for damages.

Prohibition of specification changes and modifications

Strict prohibition against changing specifications or making modifications to flameproof apparatus.