User’s
Manual
Yokogawa Electric Corporation
IM 01F06A00-01E
Model DY
Vortex Flowmeter
(Integral Type, Remote Type)
Model DYA
Vortex Flow Converter
(Remote Type)
IM 01F06A00-01EN
13th Edition

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DY200 and is the answer not in the manual?

YOKOGAWA DY200 Specifications

General IconGeneral
TypeDigital Multimeter
Diode TestYes
DisplayLCD
MountingHandheld
DC Voltage Ranges400 mV, 4 V, 40 V, 400 V
AC Voltage Ranges4 V, 40 V, 400 V, 600 V
DC Current Ranges400 µA, 4000 µA
Resistance Ranges400 Ω, 4 kΩ, 40 kΩ, 400 kΩ, 4 MΩ, 40 MΩ
Continuity CheckYes
Sampling Rate3 times/second
Power Supply1.5 V
Operating Temperature0°C to 40°C

Summary

USING THE VORTEX FLOWMETER SAFELY

Installation, Wiring, Operation, and Maintenance Safety

Covers safety for installation, wiring, operation, maintenance, and explosion-protected types.

2. INSTALLATION

Installation Location Precautions

Guidelines for selecting suitable installation sites, considering temperature, atmosphere, and vibration.

Piping Requirements and Considerations

Covers piping support, direction, adjacent pipes, straight pipe lengths, and valve position.

2.6 Flowmeter Installation Procedures

Wafer Type Installation Guidance

Step-by-step guide for installing wafer type flowmeters, including horizontal and vertical orientations.

2.7 Converter Installation

Flange Type and Remote Converter Mounting

Instructions for installing flange type flowmeters and mounting the remote converter.

3. WIRING

Wiring Precautions and Safety

Covers essential wiring safety rules, ambient temperature, cable splicing, and power handling.

Output Signal Wiring Configurations

Explains wiring for analog output, pulse output, and simultaneous analog-pulse output.

3.3 Connection Examples

Terminal Connections for Integral and Remote Types

Shows terminal layouts and connection examples for integral and remote types, referencing Figure 3.2.

3.5 Remote Type Signal Cable Connection

DYC Signal Cable Connections

Instructions for connecting the DYC signal cable between the remote flowmeter and converter.

3.6 Signal Cable Finishing Procedures

Preparing Signal Cable Ends for Flowmeter and Converter

Step-by-step guide for finishing signal cable ends for both flowmeter (DY-N) and converter (DYA).

3.8 Grounding

Grounding Terminals and Requirements

Information on grounding terminals, procedures for pulse output, and resistance requirements.

4.4 Setting Mode

Structure of Setting Mode Display and Flowchart

Explains the structure of the setting mode and provides a flowchart for parameter setting procedures.

4.4.2 Parameter Setting Methods

Numeric Data Input and Selection Item Changes

Detailed steps for adjusting numeric parameters (e.g., span) and changing selection items (e.g., output type).

4.5 BT200 Terminal Operation

Connecting BT200 and Performing Operations

Covers connecting the BT200 terminal and performing operations like displaying flow data and setting parameters.

4.5.3 Setting Parameters via BT200

Adjusting Flow Span Parameter

Detailed steps for setting the flow span parameter using the BT200 terminal interface.

4.6 HART Configuration Tool Operation

5. PARAMETER SETUP

5.3 Parameter List Overview

5.4 Parameter Descriptions

5.5 Error Code Lists

Comprehensive List of Error Codes and Recovery

A comprehensive list of error codes, their causes, indications, and recovery measures.

6. OPERATION

6.1 Adjustments: Zero, Span, and Loop Test

Procedures for adjusting the flowmeter, including zero and span adjustments and performing loop tests.

6.1 Pulse Output Scaling and Burnout Switch Settings

6.1.8 Power Failure and 6.2 Manual Mode Adjustment

7. MAINTENANCE

General Maintenance Precautions and Safety

Important cautions regarding disassembly, personnel requirements, power-off procedures, and flameproof instrument handling.

7.1 Changing the Terminal Box Orientation

7.2 Indicator and Amplifier Unit Procedures

7.5 Vortex Shedder Removal

Shedder Removal and Reassembly Procedures

Detailed steps for removing and reinstalling the vortex shedder assembly, including torque values and gasket replacement.

7.6 Flow Calculation Methods

8. TROUBLESHOOTING

Diagnosing and Resolving Flow Rate Issues

Flowcharts and solutions for common flow issues like fluctuating readings, no output, and zero output indication.

8.2 Flow Troubleshooting (/MV Models)

Specific Troubleshooting for /MV Models

Troubleshooting flowchart specifically for /MV models when starting flow, covering diagnostics, power, parameters, and sensor checks.

9.3 Model and Suffix Codes

9.4 Option Specifications

9.4.2 Option Multi-Variable (/MV) Specifications

9.4.3 OPTION REDUCED BORE TYPE (/R1) Specifications

9.4.4 Explosion Protected Type Options

9.5 Sizing and Accuracy Specifications

Calculation Formula

10. EXPLOSION PROTECTED TYPE INSTRUMENT

10.1.5 & 10.1.6 ATEX Installation Diagrams

10.2 FM Explosion Protection

10.2.5 FM Installation Diagrams

10.3 SAA Explosion Protection

10.3.5 SAA Installation Diagrams

10.4 CSA Explosion Protection

10.4.5 CSA Intrinsically Safe Installation Diagram

10.5 TIIS Explosion Protection

TIIS Flameproof Equipment Precautions

General Precautions and Terminology

General precautions for flameproof apparatus, including certification, labeling, and definitions of key terms.

Flameproof Construction and Electrical Apparatus

Defines flameproof construction and its purpose in preventing explosion ignition.

4. Installation of Flameproof Apparatus

Installation Area and Environmental Conditions

Guidelines for installing flameproof apparatus in hazardous areas and standard environmental conditions.

5. External Wiring for Flameproof Apparatus

Cable Wiring Requirements and Protection

Rules for cable wiring, including cable glands, grounding, protective pipes, and branch connections.

6. Maintenance of Flameproof Apparatus

Maintenance, Repair, and Modification Prohibitions

Precautions for maintenance, repair procedures, and prohibition of modifications to flameproof apparatus.

7. Cable Entry Devices for Flameproof Type