EasyManua.ls Logo

YOKOGAWA DY050

YOKOGAWA DY050
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
User’s
Manual
Yokogawa Electric Corporation
IM 01F06A00-01E
Model DY
Vortex Flowmeter
(Integral Type, Remote Type)
Model DYA
Vortex Flow Converter
(Remote Type)
IM 01F06A00-01EN
13th Edition

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DY050 and is the answer not in the manual?

YOKOGAWA DY050 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDY050
CategoryMeasuring Instruments
LanguageEnglish

Summary

2. INSTALLATION

2.6 Installing the Vortex Flow meter

Detailed instructions for installing wafer and flange type flowmeters, including alignment.

3. WIRING

3.1 Wiring Precautions

Essential precautions for wiring, including temperature, environment, and explosion protection.

3.2 Wiring for Output Condition

Explains wiring for analog output, pulse output, and simultaneous analog-pulse output.

3.3 Connection

Illustrates connection diagrams for integral and remote type devices.

3.5 Connection of the Remote Type Signal Cable

Details on connecting the remote type signal cable (DYC) between flowmeter and converter.

3.6 Method of Finishing the Signal Cable End(DYC)

Step-by-step guide for preparing signal cable ends for flowmeter and converter.

3.8 Grounding

Guidelines for proper grounding of the instrument and shielded cables.

4. BASIC OPERATING PROCEDURES

4.1 Construction of the Display

Describes the components and layout of the flowmeter's display panel.

4.2 Display Contents in Display Section

Explains the different display modes and their contents.

4.3 Display Contents in Display Section

Details the six available display modes for flow rate and totalized values.

4.4 Setting Mode

Overview of the setting mode for checking and rewriting parameters.

4.5 Operation for the BRAIN Terminal (BT200)

Procedures for operating the flowmeter using the BRAIN Terminal (BT200).

4.6 Operation via HART configuration tool

Guide to operating the flowmeter using a HART configuration tool.

5. PARAMETER SETUP

5.1 Parameter Setup

General information about parameter setup before factory shipment.

5.3 Parameters List

Describes the structure and content of the parameter lists.

5.4 Parameter Description

Detailed descriptions of parameters in Item A (Display).

5.5 Error Code Lists

Lists and explains error codes displayed by self-check and their recovery measures.

6. OPERATION

6.1 Adjustment

Procedures for instrument adjustment, starting with zero adjustment.

6.2 Adjustment for Manual Mode

Manual adjustments, noting that automatic adjustment is usually sufficient.

7. MAINTENANCE

8. TROUBLESHOOTING

10. EXPLOSION PROTECTED TYPE INSTRUMENT

11. PRESSURE EQUIPMENT DIRECTIVE

Related product manuals