EasyManuals Logo

York P2DP Series User Manual

York P2DP Series
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
C
3/4
28-1/2
A
20
40
FRONT LEFT SIDE
RIGHT SIDE
OPTIONAL SIDE
RETURN CUT-OUT
(EITHER SIDE)
14
GAS OUTLET
1-1/4" X 2-1/2"
2
2-1/4
1-1/8
D
(Vent Connection)
14-3/4
5-3/4
23-1/2
8-3/4
2-1/2
16
13-3/4
POWER WIRING
ACCESS
WIRING
7/8" K.O.
32-1/2
T'STAT WIRING
7/8" K.O.
7/8" HOLE
IAMON
80
D
D
Model
Air Temp
Rise °F
Max.
Outlet
Temp.
°F
Blower Total
Unit
Amps
Max.
Over-
Current
Breaker
Min. Wire
Size
(AWG)
@ 75 Ft.
One Way
Recommended
High
Velocity Filter Size Weight
(lbs)
U.S.
Models
Canada
Models
HP Size
Side Bottom
PMPD08
*
03201
10-40 25-55 180 1/4 9 x 6 12 15 14 16 X 25 12 X 27 85
P
MPD08
*
04801
35-65 45-75 180 1/6 10 x 7 12 15 14 16 X 25 16 X 27 98
P2MPD12
*
04801
25-55 180 1/2 10 x 7 12 15 14 16 X 25 16 X 27 102
P
MPD12
*
06401
25-55 50-80 180 1/2 10 x 7 12 15 14 16 X 25 16 X 27 115
P2MPD16
*
06401
20-50 180 1/2 10 x 10 12 15 14 16 X 25 20 X 27 119
P
MPD14
*
08001
30-60 45-75 180 1/2 10 x 9 12 15 14 16 X 25 20 X 27 130
P2MPD20
*
08001
30-60 180 3/4 11 x 10 13.8 15 14 16 X 25 20 X 27 135
P2MPD16
*
09601
30-60 180 3/4 10 x 9 13.0 15 14 16 X 25 20 X 27 146
P2MPD20
*
09601
25-55 180 3/4 11 x 10 13.8 15 14 16 X 25 20 X 27 151
P2MPD20
*
11201
35-65 180 3/4 11 x 10 13.8 15 14 16 X 25 25 X 27 163
Variable Speed Blower Models
P2MPV12N06401 25-55 180 1/2 10 x 7 12 15 14 16 X 25 16 X 27 119
P2MPV14N08001 30-60 180 1/2 10 x 9 12 15 14 16 X 25 20 X 27 135
P2MPV20N08001 30-60 180 1 11 x 10 12 15 14 16 X 25 20 X 27 140
NOTES: 1. Filters may be provided as an accessory or field supplied. High velocity type must be used
2. All airflow over 1800 cfm requires return air from both side inlets or bottom
Model number may be "2" for U.S.models or "9" for Canadian models.
*
Model designator may be "N" for standard units, or "L" for factory built low NOx units. Canadian units offered only as "N" models.
TABLE 2 - RATINGS & PHYSICAL/ELECTRICAL DATA
FIGURE 1 - UPFLOW FURNACE DIMENSIONS
Model ABCD
P
MPD08
*
03201
12-1/4 10 11 3
P
MPD08
*
04801
16-1/4 14 15 3
P2MPD12
*
04801
16-1/4 14 15 3
P
MPD12
*
06401
16-1/4 14 15 4
P2MPD16
*
06401
22-1/4 20 21 4
P
MPD14
*
08001
22-1/4 20 21 4
P2MPD20
*
08001
22-1/4 20 21 4
P2MPD16
*
09601
22-1/4 20 21 4
P2MPD20
*
09601
22-1/4 20 21 4
P2MPD20
*
11201
26-1/4 24 25 4
Variable Speed Blower Models
P2MPV12N06401 16-1/4 14 15 4
P2MPV14N08001 22-1/4 20 21 4
P2MPV20N08001 22-1/4 20 21 4
Vent Connection
D
(vent size)
20
C
1-1/8
A
B
5/8
26-3/4
FRONT
1-1/8
All dimensions are in inches and are approximate.
650.69-N3
4 Unitary Products Group

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the York P2DP Series and is the answer not in the manual?

York P2DP Series Specifications

General IconGeneral
BrandYork
ModelP2DP Series
CategoryFurnace
LanguageEnglish

Related product manuals