BLOWER PERFORMANCE - UPFLOW/HORIZONTAL - CFM (Includes Filter)
MODEL
SPEED
TAP
EXTERNAL STATIC PRESSURE, INCHES W.C.
0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00
P2MPD08N03201
(See Note 1)
HIGH 1150 1090 1021 945 877 791 670 458
MED 1027 971 930 862 790 714 597 411
LOW 846 817 782 726 673 608 500 317
P2MPD08N04801
(See Note 3)
HIGH 998 965 934 878 827 769 665 576 489 323
MED 890 858 824 775 741 660 584 504
LOW——————————
P2MPD12N04801
(See Note 2)
HIGH 1548 1480 1396 1312 1270 1126 1029 908 736 563
MED 1275 1221 1180 1152 1080 1016 922 807 657 482
LOW 1055 1050 1034 998 960 888 773 645 446
P2MP12N06401
(See Note 2)
HIGH 1605 1538 1427 1331 1284 1178 1080 978 815 619
MED 1172 1195 1140 1102 1076 985 908 822 682 5663
LOW 967 932 925 885 851 763 630
P2MPD16N06401
(See Note 3)
HIGH 1967 1884 1795 1697 1605 1477 1340 1167 986 799
MED 1822 1758 1673 1592 1512 1399 1256 1107 917 742
LOW 1440 1383 1330 1240 1142 986 841 702
P2MPN14N08001
(See Note 3)
HIGH 1861 1798 1698 1584 1494 1364 1258 1087 898 756
MED 1569 1503 1438 1375 1277 1182 1071 928 772 643
LOW 1295 1270 1198 1156 1063 966 857 725 616
P2MPD20N08001
(See Notes 4, 7)
HIGH 2380 2318 2243 2195 2107 2017 1944 1811 1703 1583
MED 1989 1976 1967 1949 1907 1832 1755 1680 1566 1477
LOW 1585 1570 1527 1502 1447 1398 1333 1248
P2MPD16N09601
(See Note 4)
HIGH 2117 2023 1920 1821 1731 1587 1459 1302 1045 818
MED 1905 1821 1743 1649 1563 1465 1332 1168 957 643
LOW 1546 1532 1495 1424 1357 1268 1155 1000 840 663
P2MPD20N09601
(See Notes 5, 7)
HIGH 2367 2342 2270 2198 2110 2004 1913 1797 1581
MED 2027 1986 1945 1917 1877 1820 1763 1653 1558 1445
LOW 1349 1327 1312 1281 1233 1150 1078
P2MPD20N11201
(See Notes 6, 7)
HIGH 2204 2154 2081 2055 2002 1933 1843 1706 1545 1409
MED 1805 1779 1758 1715 1656 1579 1507 1395 1292
LOW 1451 1451 1423 1377 1284 1201 1095
P9MPD08N03201
(See Note 1)
HIGH 1175 1020 995 890 835 740 685
MED 950 920 885 810 710 650 605
LOW 625 605 595 580 550
P9MPD08N04801
(See Note 3)
HIGH 998 965 934 878 827 769 665 576 489
MED 890 858 824 775 741 660 584 504
LOW 684 650 610 506 521 469
P9MPD12N06401
(See Note 2)
HIGH 1475 1437 1395 1325 1235 1150 1030 915 755
MED 1220 1195 1130 1085 1040 965 870 763
LOW 805 795 765 750 725
P9MPD14N08001
(See Note 3)
HIGH 1670 1620 1565 1485 1410 1305 1145 955 790
MED 1370 1355 1310 1265 1205 1125 975 865
LOW 1085 1060 1035 1005 995 925
P2MPV12N06401
1200**
CFM
SETTING
1200 1200 1200 1200 1200 1200 1200 1200
P2MPV14N08001
1400**
CFM
SETTING
1400 1400 1400 1400 1400 1400 1400 1400 1400 1400
P2MPV20N08001
(See Note 7)
2000**
CFM
SETTING
2000 2000 2000 2000 2000 2000 2000 2000 2000
These conditions are outside the recommended heating operating range.
Airlfow is expressed in standard cubic feet per minute.
Motor voltage at 115V
** Other CFM settings are available.
Figures shown are for left side return air installation, except for the D20 units which must use both sides for applications over 1800
CFM. All units may use bottom only return, see correction factors listed in Notes 1-6.
NOTES:
1 - CFM shown x .90 5 - CFM shown x .91
2 - CFM shown x .98 6 - CFM shown x .96
3 - CFM shown x .97 7 - Air flow shown is with return air from both sides.
4 - CFM shown x .93 Use the derate factors for bottom only return
650.69-N3
Unitary Products Group 21

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the York P2DP Series and is the answer not in the manual?

York P2DP Series Specifications

General IconGeneral
BrandYork
ModelP2DP Series
CategoryFurnace
LanguageEnglish

Related product manuals