127421-YIM-C-0606
20 Unitary Products Group
TABLE 15: ELECTRICAL DATA BP120 (10 TON) HP W/O PWRD CONVENIENCE OUTLET
RL
LR
FL
23 2 3 2 3232 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 51.2 53.9 56.7 59.4 60 60 70 70
2TP04521825 13.5 37.5 98.0 100.7 103.5 106.2 100 110 110 110
2TP04522425 18.0 50.0 113.7 116.4 119.2 121.9 125 125 125 125
2TP04523625 25.5 70.8 139.7 142.4 145.2 147.9 150 150 150 150
2HP04525425** 40.6 112.7 151.1 154.5 158.0 161.4 175 175 175 175
None -- -- 51.2 53.9 56.7 59.4 60 60 70 70
2TP04521825 18.0 43.3 105.3 108.0 110.8 113.5 110 110 125 125
2TP04522425 24.0 57.7 123.4 126.1 128.9 131.6 125 150 150 150
2TP04523625 34.0 81.8 153.4 156.1 158.9 161.6 175 175 175 175
2HP04525425** 54.0 129.9 153.4 156.1 158.9 161.6 175 175 175 175
None -- -- 29.6 30.8 31.8 33 35 40 40 40
2TP04521846 18 22.6 56.6 57.8 58.8 60 60 60 60 60
2TP04522446 24 30.1 65.7 66.9 67.9 69.1 70 70 70 70
2TP04523646 34 42.7 80.7 81.9 82.9 84.1 90 90 90 90
2HP04535446** 54 67.8 80.7 81.9 82.9 84.1 90 90 90 90
None -- -- 20.6 21.1 22.4 22.9 25 25 25 25
2TP04521858 18 18.1 42.3 42.8 44.1 44.6 45 45 45 45
2TP04522458 24 24.1 49.5 50 51.3 51.8 50 50 60 60
2TP04523658 34 34.1 61.5 62 63.3 63.8 70 70 70 70
2HP04535458** 54 54.2 61.5 62 63.3 63.8 70 70 70 70
*
** Only 34 kW of Electric heat can be simultaneously energized with the mechanical heating. The full 54 kW operates only if both compressors are
locked-out.
Maximum HACR breaker of the same AMP size is applicable.
2.2 0.0
6.4 62.0 1.3 3.6 4.1 1.8 0.0
75.0 1.6 4.1
150.0 3.5 8.2
3.5 8.2 10.9150.0 5.5 0.0
5.5 0.0
5.3
10.9
460
575
9.9
208
230
16.0
16.0
Max Fuse Size*
w/Power
Exhaust
(Amps)
FLA FLA
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Pwr
Exh
Motor
Pwr
Conv
Outlet
Electric Heater
Model No.
Max
Fuse*
Size
(Amps)
Voltage
Compressors
OD Fan
Motors
Supply
Blower
Motor FLA
TABLE 16: ELECTRICAL DATA BP120 (10 TON) HP WITH PWRD CONVENIENCE OUTLET
RL
LR
FL
23 2 3 2 3232 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 61.2 63.9 66.7 69.4 70 70 80 80
2TP04521825 13.5 37.5 108.0 110.7 113.5 116.2 110 125 125 125
2TP04522425 18.0 50.0 123.7 126.4 129.2 131.9 125 150 150 150
2TP04523625 25.5 70.8 149.7 152.4 155.2 157.9 150 175 175 175
2HP04525425** 40.6 112.7 163.6 167.0 170.5 173.9 175 175 175 175
None -- -- 61.2 63.9 66.7 69.4 70 70 80 80
2TP04521825 18.0 43.3 115.3 118.0 120.8 123.5 125 125 125 125
2TP04522425 24.0 57.7 133.4 136.1 138.9 141.6 150 150 150 150
2TP04523625 34.0 81.8 163.4 166.1 168.9 171.6 175 175 175 175
2HP04525425** 54.0 129.9 163.4 166.1 168.9 171.6 175 175 175 175
None -- -- 34.6 35.8 36.8 38 40 45 45 45
2TP04521846 18 22.6 61.6 62.8 63.8 65 70 70 70 70
2TP04522446 24 30.1 70.7 71.9 72.9 74.1 80 80 80 80
2TP04523646 34 42.7 85.7 86.9 87.9 89.1 90 90 90 90
2HP04535446** 54 67.8 85.7 86.9 87.9 89.1 90 90 90 90
None -- -- 24.6 25.1 26.4 26.9 30 30 30 30
2TP04521858 18 18.1 46.3 46.8 48.1 48.6 50 50 50 50
2TP04522458 24 24.1 53.5 54 55.3 55.8 60 60 60 60
2TP04523658 34 34.1 65.5 66 67.3 67.8 70 70 70 70
2HP04535458** 54 54.2 65.5 66 67.3 67.8 70 70 70 70
*
** Only 34 kW of Electric heat can be simultaneously energized with the mechanical heating. The full 54 kW operates only if both compressors are
locked-out.
1.8 4.0
Maximum HACR breaker of the same AMP size is applicable.
62.0 1.3 3.6 4.1
10.0
9.9 75.0 1.6 4.1 5.3 2.2 5.0
150.0 8.2 10.9
16.0 150.0 3.5 8.2 10.9 5.5
5.5
10.0
Max
Fuse*
Size
(Amps)
Supply
Blower
Motor FLA
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA FLA
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Pwr
Exh
Motor
Pwr
Conv
Outlet
Electric Heater
Model No.
Voltage
Compressors
OD Fan
Motors
460
3.5
575
6.4
208
230
16.0