127421-YIM-C-0606
Unitary Products Group 47
TABLE 52: COOLING SUPERHEAT 7-1/2 TON HEAT PUMP
OUTDOOR
TEMP °F
SUCTION SUPERHEAT °F
INDOOR WB TEMP °F
55 57 59 61 63 65 67 69 71 73 75
65
29.2 31.9 34.6 37.3 40.1 42.8 45.5 46.5 47.6 48.6 49.7
70
27.1 29.7 32.2 34.8 37.3 39.9 42.4 43.5 44.5 45.6 46.7
75
25.0 27.4 29.8 32.2 34.5 36.9 39.3 40.4 41.5 42.6 43.7
80
22.9 25.2 27.4 29.6 31.8 34.0 36.2 37.3 38.5 39.6 40.7
85
20.9 22.9 24.9 27.0 29.0 31.1 33.1 34.3 35.4 36.6 37.7
90
14.8 17.4 19.9 22.4 24.9 27.5 30.0 31.7 33.4 35.2 36.9
95
8.8 11.8 14.8 17.8 20.9 23.9 26.9 29.2 31.5 33.7 36.0
100
7.8 10.1 12.4 14.7 16.9 19.2 21.5 24.6 27.8 30.9 34.1
105
6.9 8.4 9.9 11.5 13.0 14.5 16.1 20.1 24.1 28.1 32.1
110
5.9 6.7 7.5 8.3 9.1 9.8 10.6 15.5 20.4 25.3 30.2
115
5.0 5.1 5.1 5.2 5.2 11.0 16.7 22.5 28.2
TABLE 53: COOLING SUPERHEAT 8-1/2 & 10 TON HEAT PUMP
OUTDOOR
TEMP °F
SUCTION SUPERHEAT °F
INDOOR WB TEMP °F
55 57 59 61 63 65 67 69 71 73 75
65
29.9 31.5 33.1 34.7 36.3 37.9 39.5 39.5 39.5 39.5 39.5
70
25.5 27.1 28.7 30.4 32.0 33.6 35.2 35.8 36.3 36.9 37.5
75
21.1 22.8 24.4 26.0 27.7 29.3 31.0 32.1 33.2 34.3 35.4
80
16.7 18.4 20.0 21.7 23.4 25.1 26.7 28.4 30.0 31.7 33.4
85
12.3 14.0 15.7 17.4 19.1 20.8 22.5 24.7 26.9 29.1 31.3
90
12.0 13.4 14.8 16.2 17.6 19.0 20.4 22.4 24.4 26.4 28.4
95
11.6 12.8 13.9 15.0 16.1 17.2 18.3 20.1 21.9 23.6 25.4
100
8.9 9.7 10.6 11.4 12.2 13.0 13.9 15.5 17.1 18.7 20.3
105
6.2 6.7 7.3 7.8 8.3 8.9 9.4 10.9 12.3 13.8 15.3
110
-------6.3 7.6 8.9 10.2
115
----------5.1