036-21539-003-B-0305
4 Unitary Products Group
PRODUCT NOMENCLATURE
15 - 25T Sunline MagnaDRY™ Model Number Nomenclature
DR300N24 A 2A AA 1A
Product Category Product Style
D = Air Cond., Single Package A=StyleA
Product Generation
1 = First Generation
2 = Second Generation
Product Identifier
R = R-22 Reheat Unit
Installation Options
Additional Options
A = No Options Installed
(See Next Page)
Voltage B=Option1
1 = 208/230-1-60 C = Option 2
2 = 208/230-3-60 D = Options 1 & 2
Nominal Cooling Capacity - MBH 4 = 460-3-60 E = Option 3
5 = 575-3-60 F = Options 4
G=Options1&3
H = Options 1 & 4
180 = 15 Ton
240 = 20 Ton
300 = 25 Ton
J = Options 1, 2 & 3
K = Options 1, 2, & 4
A = Std Motor/Drive
L = Options 1,3 & 4
B = Std Mtr/Drive/Single Input Econo
M = Options 1, 2, 3, & 4
C = Std Mtr/Drive/Single Input Econo/Power Exhaust
N = Options 2 & 3
D = Std Mtr/Drive/Motorized Damper
P=Options2&4
Heat Type & Nominal Heat Capacity
F = Std Mtr/Drive/4" Filters
Q = Options 2, 3, & 4
C00 = Cooling Only. No field installed electric heat
G = Std Mtr/Drive/4" Filters/Single Input Econ
R = Options 3 & 4
Gas Heat Options
H = Std Mtr/Drive/4" Filters/Single Input Econ/Power Exhaust
S=Option5
N24 = 240 MBH Output Aluminized Steel
L = Std Mtr/Drive/BAS Ready Econ (No BAS Controller) w/2" Pleated Filters
T=Options1&5
N32 = 320 MBH Output Aluminized Steel, (15-25T Only)
M = Std Mtr/Drive/BAS Ready Econ (No BAS Controller)/Power Exhaust w/2" Pleated Filters
U = Options 1, 3, & 5
S24 = 240 MBH Output Stainless Steel
N = Hi Static Drive
V = Options 1, 4, & 5
S32 = 320 MBH Output Stainless Steel, (15-25T Only)
P = Hi Static Drive/Single Input Econo
W = Options 1, 3, 4, & 5
Electric Heat Options
Q = Hi Static Drive/Single Input Econo/Power Exhaust
X = Options 3 & 5
E18 = 18 KW
R = Hi Static Drive/Motorized Damper
Y=Options4&5
E36 = 36 KW
T = Hi Static Drive/4" Filters
Z = Options 3, 4, & 5
E54 = 54 KW
U = Hi Static Drive/4" Filters/Single Input Econ
Options
E72 = 72 KW
V = Hi Static Drive/4" Filters/Single Input Econ/Power Exhaust
1 = Disconnect
Y = Hi Static Drive/BAS Ready Econ (No BAS Controller) w/2" Pleated Filters
2 = Non-Pwr'd Conv Oultet
Z = Hi Static Drive/BAS Ready Econ (No BAS Controller)/Power Exhaust w/2" Pleated Filters
2 = Low Static Drive - 25 Ton only
3 = Low Static Drive/Single Input Econo - 25 Ton only
4 = Low Static Drive/Single Input Econo/Power Exhaust - 25 Ton only
5 = Low Static Drive/Motorized Damper - 25 Ton only
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet
Airflow
York Brand