JOHNSON CONTROLS
9
FORM 150.62-EG1 (507)
additional application recommendations, refer to FORM
150.12-ES1. (Factory-mounted.)
PRE-COATED FIN CONDENSER COILS The air-
cooled condenser coils are constructed of black ep-
oxy-coated aluminum ns. This can provide corrosion
resistance comparable to copper-n coils in typical
seashore locations. Either these or the post-coated coils
(below), are recommended for units being installed at
the seashore or where salt spray may hit the unit.
POST-COATED DIPPED CONDENSER COILS – The
unit is built with dipped-cured condenser coils. This is
another choice for seashore and other corrosive appli-
cations (with the exception of strong alkalies, oxidizers
and wet bromine, chlorine and uorine in concentrations
greater than 100 ppm).
COPPER FIN CONDENSER COILS The unit con-
structed with condenser coils which have copper ns.
(This is not recommended for units in areas where they
may be exposed to acid rain.)
ENCLOSURE PANELS (UNIT) – Tamperproof Enclosure
Panels prevent unauthorized access to units. Enclosure
Panels can provide an aesthetically pleasing alternative
to expensive fencing. Additionally, for proper head pres-
sure control, YORK recommends the use of Condenser
Louvered Panels for winter applications where wind gustss
may exceed ve miles per hour. The following types of
enclosure panels are available:
WIRE PANELS (Full Unit) Consists of welded wire-
mesh guards mounted on the exterior of the unit. Pre-
vents unauthorized access, yet provides free air ow.
(Factory-mounted.)
WIRE/LOUVERED PANELS Consists of welded wire-
mesh panels on the bottom part of unit and louvered
panels on the condenser section of the unit. (Factory-
mounted).
LOUVERED PANELS (Condenser Coil Only) Lou-
vered panels are mounted on the sides and ends of the
condenser coils for protection. (Factory-mounted.)
LOUVERED PANELS (Full Unit) Louvered panels
surround the front, back, and sides of the unit. They
prevent unauthorized access and visually screen unit
components. Unrestricted air ow is permitted through
generously sized louvered openings. This option is ap-
plicable for any outdoor design ambient temperature up
to 115°F (46°). (Factory-mounted.)
SOUND ATTENUATION One or both of the following
sound attenuation options are recommended for residential
or other similar sound sensitive locations:
COMPRESSOR ACOUSTIC SOUND BLANKET
Each compressor is individually enclosed by an
acoustic sound blanket. The sound blankets are made
with one layer of acoustical absorbent textile ber of
5/8" (15mm) thickness; one layer of anti-vibrating heavy
material thickness of 1/8" (3mm). Both are closed by two
sheets of welded PVC, reinforced for temperature and
UV resistance. (Factory-mounted.)
LOW SOUND FANS Lower RPM, 8-pole fan motors
are used with steeper-pitch fans. (Factory-mounted.)
VIBRATION ISOLATORS Level adjusting, spring type 1"
(25.4mm) or seismic deection or neoprene pad isolators
for mounting under unit base rails. (Field-mounted.)