571209-YTG-B-1211
Johnson Controls Unitary Products 7
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT MODEL
FURNACE**
COIL
MODEL
COOLING
CFM RANGE
(Min.-max.)
WIDTH
RATED
CFM
NET MBH
SEER
1
EER
TOTAL SENS.
YHJD18S41S2
450 - 750 14,17 FC/MC/PC18 600 18.0 14.0 13.00 11.00
450 - 750 14,17 FC/MC/PC24 600 18.0 14.0 13.50 11.00
450 - 750 14 HD24 600 18.0 14.0 13.50 11.00
YHJD24S41S4
600 - 1000 14 FC/MC/PC32 800 23.8 17.1 13.00 11.00
600 - 1000 17,21 FC/MC/PC35 800 23.6 17.1 13.00 11.00
600 - 1000 14 FC/MC/PC37 800 24.0 17.3 13.00 11.00
600 - 1000 17,21 FC/MC/PC43 800 24.0 17.3 13.00 11.00
YHJD30S41S4
800 - 1200 14 FC/MC/PC32 1000 29.8 21.8 13.00 11.00
800 - 1200 17,21 FC/MC/PC35 1000 29.8 21.8 13.00 11.00
800 - 1200 14 FC/MC/PC37 1000 30.0 22.2 13.00 11.00
800 - 1200 17,21 FC/MC/PC43 1000 30.0 22.2 13.00 11.00
YHJD36S41S4
1000 - 1400 17,21 FC/MC/PC43 1200 36.0 26.6 13.00 11.00
1000 - 1400 14 FC/MC/PC37 1200 36.0 26.8 13.00 11.00
1000 - 1400 – HD48 1200 36.0 26.4 13.00 11.00
1000 - 1400 21,24 FC/MC/PC48 1200 36.0 26.6 13.00 11.00
1000 - 1400 21,24 UC48 1200 36.0 26.8 13.00 11.00
YHJD42S41S4
1200 - 1600 21,24 FC/MC/PC60 1400 41.0 31.8 13.00 11.00
1200 - 1600 – HD60 1400 41.0 31.4 13.00 11.00
1200 - 1600 21,24 UC60 1400 40.5 31.0 13.00 11.00
YHJD48S41S4
1400 - 1800 21,24 FC/MC/PC60 1600 44.0 33.4 13.00 11.00
1400 - 1800 24 FC/MC62 1600 44.5 33.8 13.00 11.00
1400 - 1800 21,24 UC60 1600 44.0 32.8 13.00 11.00
YHJD60S41S4
1600 - 2000 24 FC/MC62 1800 55.0 40.0 13.00 11.00
1600 - 2000 24 FC64 1800 56.0 41.5 13.00 11.00
1. Requires a S1-2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
MA Modular Air Handlers use Coil Only Ratings.