5167821-YTG-K-1118
Johnson Controls Ducted Systems 57
115°F 125°F
2500
77 123.5 9.3 50.4 43.4 32.3 - - - 113.9 10.3 44.6 40.0 29.0 - - -
72 113.1 9.2 71.4 60.3 49.1 37.9 - - 104.5 10.2 67.5 56.4 45.4 34.3 - -
67 102.7 9.2 92.5 77.1 65.9 54.8 43.6 - 95.1 10.2 90.2 72.8 61.8 50.7 39.7 -
62 98.6 9.1 98.6 95.1 77.9 66.7 55.6 44.4 95.9 10.1 95.9 90.6 72.4 61.3 50.3 39.2
3000
77 125.6 9.3 60.8 48.1 35.3 - - - 115.3 10.3 57.1 44.4 31.8 - - -
72 115.0 9.3 79.2 66.4 53.6 40.9 - - 105.8 10.3 75.1 62.4 49.8 37.2 - -
67 104.4 9.2 97.6 84.8 72.0 59.2 46.4 - 96.3 10.2 93.1 80.5 67.8 55.2 42.5 -
62 100.2 9.1 100.2 97.9 85.1 72.3 59.5 46.7 97.1 10.1 97.1 93.6 79.4 66.8 54.2 41.5
57 101.5 8.9 101.5 99.1 86.3 73.5 60.7 47.9 98.6 9.8 98.6 95.0 80.8 68.2 55.5 42.9
3500
77 127.7 9.3 71.3 52.7 38.2 - - - 116.7 10.3 69.6 48.9 34.6 - - -
72 116.9 9.3 87.0 72.6 58.2 43.8 - - 107.1 10.3 82.7 68.5 54.2 40.0 - -
67 106.1 9.2 102.7 92.5 78.1 63.7 49.3 - 97.5 10.2 96.0 88.1 73.8 59.6 45.4 -
62 101.9 9.1 101.9 100.7 92.3 77.9 63.5 49.1 98.4 10.1 98.4 96.6 86.5 72.3 58.0 43.8
57 103.2 8.9 103.2 102.0 93.6 79.2 64.8 50.4 99.9 9.8 99.9 98.1 88.0 73.8 59.5 45.3
4000
77 129.8 9.4 81.7 57.3 41.2 - - - 118.1 10.4 82.1 53.3 37.5 - - -
72 118.8 9.3 94.8 78.8 62.7 46.7 - - 108.4 10.3 90.3 74.5 58.7 42.8 - -
67 107.8 9.2 107.8 100.2 84.2 68.2 52.2 - 98.6 10.2 98.6 95.7 79.9 64.0 48.2 -
62 103.6 9.1 103.6 103.6 99.5 83.5 67.5 51.5 99.6 10.1 99.6 99.6 93.6 77.7 61.9 46.1
57 104.9 8.9 104.9 104.9 100.9 84.9 68.9 52.8 101.2 9.8 101.2 101.2 95.2 79.4 63.5 47.7
4500
72 120.1 9.3 102.0 84.5 67.1 49.6 - - 108.8 10.3 97.2 79.9 62.7 45.5 - -
67 109.0 9.2 109.0 105.2 90.1 72.6 55.1 - 99.0 10.2 99.0 99.0 85.3 68.1 50.9 -
62 104.6 9.1 104.6 104.6 102.6 85.2 67.7 50.3 100.1 10.1 100.1 100.1 97.1 79.8 62.6 45.4
57 106.0 8.9 106.0 106.0 104.0 86.5 69.1 51.6 101.7 9.8 101.7 101.7 98.7 81.4 64.2 47.0
5000
72 121.3 9.3 109.2 90.3 71.4 52.5 - - 109.2 10.2 104.0 85.4 66.7 48.1 - -
67 110.1 9.2 110.1 110.1 95.9 77.0 58.1 - 99.4 10.2 99.4 99.4 90.8 72.2 53.5 -
62 105.7 9.1 105.7 105.7 105.7 86.8 67.9 49.0 100.6 10.1 100.6 100.6 100.6 81.9 63.3 44.6
57 107.1 8.9 107.1 107.1 107.1 88.2 69.3 50.4 102.2 9.7 102.2 102.2 102.2 83.5 64.9 46.2
1. These capacities are gross ratings. For net capacity, deduct the air blower motor, MBh = 3.415 x kW. Refer to the appropriate blower
performance table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
ZT120 (10 ton) 3rd stage cooling (continued)
Air on evaporator
coil
Temperature of air on condenser coil
Total
capacity
1
(MBh)
Total input
(kW)
2
Sensible capacity (MBh)
Total
capacity
1
(MBh)
Total input
(kW)
2
Sensible capacity (MBh)
CFM
WB
(°F)
Return dry bulb (°F) Return dry bulb (°F)
90 85 80 75 70 65 90 85 80 75 70 65