75°F 85°F
3125
7771.4 5.3 ------ 66.4 5.7 ------
72 65.9 5.1 10.5 7.5 4.6 1.6 - - 61.0 5.5 9.2 6.6 4.0 1.5 - -
67 60.3 5.0 25.8 22.9 19.9 17.0 14.0 - 55.6 5.4 20.9 18.3 15.8 13.2 10.6 -
62 57.9 5.0 38.1 33.3 30.3 27.4 24.4 21.5 53.4 5.3 29.7 25.0 22.4 19.9 17.3 14.7
3750
7774.1 5.2 ------ 69.6 5.6 ------
72 68.3 5.1 13.4 9.7 6.0 2.3 - - 63.9 5.5 12.8 9.3 5.7 2.2 - -
67 62.6 5.0 33.3 29.6 25.9 22.2 18.5 - 58.2 5.3 29.9 26.4 22.9 19.4 15.9 -
62 60.1 4.9 46.9 43.1 39.4 35.7 32.0 28.3 56.0 5.3 40.1 36.6 33.1 29.6 26.1 22.6
57 58.4 4.9 48.6 44.9 41.2 37.5 33.7 30.0 54.9 5.3 41.6 38.0 34.5 31.0 27.5 24.0
4375
77 76.8 5.2 ------ 72.8 5.6 ------
72 70.8 5.1 16.3 11.8 7.3 2.9 - - 66.8 5.4 16.3 11.9 7.4 3.0 - -
67 64.9 4.9 40.9 36.4 31.9 27.4 23.0 - 60.9 5.3 38.9 34.5 30.0 25.6 21.1 -
62 62.3 4.9 55.7 53.0 48.5 44.1 39.6 35.1 58.5 5.2 50.6 48.2 43.8 39.3 34.9 30.4
57 60.5 4.9 55.6 53.8 50.7 46.2 41.7 37.2 57.4 5.3 50.7 49.0 45.7 41.2 36.8 32.3
5000
77 79.5 5.2 ------ 75.9 5.5 ------
72 73.3 5.0 19.2 14.0 8.7 3.5 - - 69.7 5.4 19.9 14.5 9.1 3.8 - -
67 67.2 4.9 48.4 43.1 37.9 32.6 27.4 - 63.5 5.2 47.9 42.5 37.2 31.8 26.4 -
62 64.5 4.8 64.5 62.9 57.6 52.4 47.2 41.9 61.1 5.2 61.1 59.8 54.4 49.1 43.7 38.3
57 62.6 4.8 62.6 62.6 60.2 54.9 49.7 44.5 59.9 5.2 59.9 59.9 56.8 51.4 46.0 40.7
5250
72 73.1 5.0 20.0 14.5 9.1 3.6 - - 69.1 5.3 20.6 15.0 9.4 3.9 - -
67 67.0 4.9 50.2 44.8 39.3 33.8 28.4 - 62.9 5.2 49.5 43.9 38.3 32.8 27.2 -
62 64.3 4.8 64.3 63.5 59.8 54.3 48.9 43.4 60.5 5.2 60.5 59.9 56.1 50.5 45.0 39.4
57 62.4 4.8 62.4 62.4 61.2 55.7 50.3 44.8 59.3 5.2 59.3 59.3 57.8 52.2 46.6 41.1
5500
72 72.9 5.0 20.8 15.1 9.4 3.7 - - 68.4 5.3 21.3 15.5 9.7 4.0 - -
67 66.7 4.8 52.1 46.4 40.7 35.0 29.3 - 62.3 5.2 51.0 45.3 39.5 33.7 28.0 -
62 64.1 4.8 64.1 64.1 61.9 56.3 50.6 44.9 59.9 5.1 59.9 59.9 57.8 52.0 46.2 40.5
57 62.2 4.8 62.2 62.2 62.2 56.5 50.9 45.2 58.8 5.1 58.8 58.8 58.8 53.0 47.2 41.5
1. These capacities are gross ratings. For net capacity, deduct the air blower motor, MBh = 3.415 x kW. Refer to the appropriate blower
performance table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
ZT150 (12.5 ton) reheat (continued)
Air on evaporator
coil
Temperature of air on condenser coil
Total
capacity
1
(MBh)
Total input
(kW)
2
Sensible capacity (MBh)
Total
capacity
1
(MBh)
Total input
(kW)
2
Sensible capacity (MBh)
CFM
WB
(°F)
Return dry bulb (°F) Return dry bulb (°F)
90 85 80 75 70 65 90 85 80 75 70 65