decreasing or inscreasing value get quick. The range of setpoint is between the parameter SPL and SPH. The
default range is 0~400.
● Program segment setting:
Press the key once and release in the display status, the instrument will be in the setup program status.
The set point of the current program StEP will be displayed.
Pressing 、 or can modify the value.
Pressing can go to next parameter. The program parameters will be displayed in the sequence of
setpoint1, time1, setpoint2, time2.
Pressing and holding for about 2 seconds will return to the previous parameter. Program step can modify
anytime even the program still in running.
Run / Hold only (for AI-526P)
In basic display status, if the program is in stoP status (“StoP” is alternately displayed on the lower window),
press and hold the key for about 2 seconds until the lower display window displays the "Run" symbol, the
instrument then will start the program.
If parameter “PAF” set F=1, user can hold the key for about 2 seconds, instrument will changes to hold
status and lower display window displays the "HoLd" symbol. If parameter “PAF” set F=0, “Ho ld ” status only