NOTE: Power consumption needs to increase or decrease by at least 1 Watt to be reported,
REGARDLESS of the percentage set in this parameter.
Parameter no. 42 Power reporting in Watts by time interval for Q1 or Q2
The set value refers to the time interval with which the power consumption in Watts is
reported (0 32535 seconds). If 0 is entered (by default), energy consumption reports will not
be sent to the controller.
Values (size is 2 byte dec):
default value 300
0 - Power consumption reporting disabled
1 32767 = 1 - 32767 seconds. Power consumption reporting enabled. Report is sent
according to time interval (value) set here.
Parameter no. 71 Operating modes
Choose between the two operating modes. If the venetian mode is selected, an additional
widget/endpoint will be displayed on the UI interface, which can be used to control the tilt
position of the slats. If the Shutter mode is selected, this additional endpoint is hidden.
Values (data type is 1 byte dec):
default value 0
0 - Shutter mode
1 - venetian mode (up/down and slate rotation)