44
NOTE1: After the value of this parameter is changed, first exclude module (without setting
parameters to their default values), wait at least 30s and then reinclude the module!
Parameter no. 72 Slats tilting full turn time
Set the time, required by the slats, to make a full turn (180 degrees).
Values (data type is 2 byte dec):
default value 150 = 1.5 seconds
0 - tilting time disabled
1 - 32767 = 0,01seconds 327.67 seconds
NOTE: If the set time is too long and a full turn was already performed, the device will start to
move up or down for the remaining time.