EasyManuals Logo

Z-Wave QUBINO FLUSH SHUTTER User Manual

Default Icon
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
EN.
49
Parameter no. 110 Temperature Sensor Offset Settings
Set value is added to or subtracted from the actually measured value to adjust the temperature
report sent by an external sensor (sold separately). This parameter only applies to the degrees
temperature unit (the Fahrenheit unit is currently not supported).
Values (size is 2 byte dec):
default value 32536
32536 - Offset is 0 degrees.
1 - 100 - Where 1 stands for 0.1 and 100 stands for 10.00 degrees added to the actual
measurement.
1001 - 1100 Where 1001 stands for -0.1 degrees and 1100 stands for -10.0 degrees
subtracted from the actual measurement.
Parameter no. 120 Temperature Sensor Reporting Threshold
If an external digital temperature sensor (sold separately) is connected to the module, it reports
temperature readings based on the threshold defined in this parameter. This parameter only
applies to the degrees temperature unit (the Fahrenheit unit is currently not supported).
Values (size is 1 byte dec):
Default value 5 = 0.5°C
0 Reporting disabled
1 - 127 = Where 1 stands for 0.1 and 127 stands for 12.7 degrees