5) THROTTLE 0 ZONE
It establishes a deadband in the accelerator input curve (see also curve
below).
6) THROTTLE X POINT
This parameter changes the characteristic of the accelerator input curve.
7) THROTTLE Y POINT
This parameter changes the characteristic of the accelerator input curve.
VACC MIN and VACC MAX are values programmable by the "Program
Vacc" function.
8) BATT. MIN. ADJ.
It adjusts the lower level of the battery discharge table. It is used to calibrate
the discharge algorithm with the battery of the application. See chapter 9.5
for more information.
9) BATT. MAX. ADJ.
It adjusts the upper level of the battery discharge table. It is used to calibrate
the discharge algorithm with the battery of the application. See chapter 9.5
for more information.
10) ADJUSTMENT #03
This parameter adjusts the updating of battery charge after Key-On.
Decreasing this parameter the difference between the battery voltage
measured after Key-On and the last stored value necessary to update the
charge with the new value measured decrease. It is used to calibrate the
discharge algorithm with the battery of the application. See chapter 9.5 for
more information.
11) LOAD HM FROM MDI
When set On, the HourMeter of the Controller is transferred and recorded on
the HourMeter of the Standard MDI (connected on the Serial Link).