AF2ZP0CL - ACE2 - User Manual Page - 35/85
- OFF: the stop on ramp feature is not performed.
7) AUX OUTPUT #1
- BRAKE: output A18 drives an electromagnetic brake coil which is
activated every time the traction motor is driven.
- FREE: No function.
- OPTION#1: Reverse Alarm. A18 is active when input REVERSE is
active or when motor is drived in reverse direction.
8) SET MOT. TEMPERATURE
- DIGITAL: a digital (ON/OFF) motor thermal sensor is connected
between A22 and A23 inputs.
- ANALOG: an analogue motor thermal sensor is connected between
A22 and A23 (the curve can be customized on a customer request).
- NONE: no motor thermal sensor switch is connected.
9) AUX INPUT#1
This parameter decide if input A10 is used for brake or for quick inversion.
BRAKE: A10 is used like brake pedal.
BELLY: A10 is used like quick inversion input. There’s inversion until A10 is
closed.
TIMED: A10 is used for quick inversion request and inversion is timed.
10) 2.5 POT
ON: when the potentiometer is under the half range level, is backward. When
is over is forward. Forward and backward microswitches are not present.
Enable is A4.
11) BACKING:
ON: Inching function is available. Enable input on A19, Forward direction
request input on A4, reverse direction request input on A5.
12) EPS
ON: EPS is present.
SUBMENU "ADJUSTMENTS"
1) SET POT BRK MIN
It records the minimum value of braking pedal potentiometer when the
braking switch is closed; the procedure is similar to the "Program Vacc"
function (see chapter 9.4). This procedure must be carried out only if the
"Pedal braking" option is programmed as "Analog".
2) SET POT BRK MAX
It records the maximum value of braking pedal potentiometer when the
braking pedal is fully pressed; the procedure is similar to the "Program Vacc"
function (see chapter 9.4). This procedure must be carried out only if the
"Pedal braking" option is programmed as "Analog".
3) SET BATTERY TYPE
It selects the nominal battery voltage.
4) ADJUST BATTERY
Fine adjustment of the battery voltage measured by the controller.