just pressed) then the following parameter will be used.
Autorepeat: (in milliseconds) the acceleration effect follows this
parameter.
Max idle time
It sets the stand-by time (in minutes) before the console is turned off to save
charge of the internal batteries.
The time count is not carried out if the console is supplied by an external source:
it works only when internal batteries are used.
To reset the timer it is necessary to push any button.
If the parameter is set to 0 (default value), this function is not active.
Battery type
This parameter sets the type of internal battery installed inside the holder. The
value sets the correct threshold for the low-battery indication.
The default value is NiMh because this type of battery is preferred. Otherwise it
can be set to Alkaline if non-rechargeable batteries are used.
6.2 Read Ram and Read Eeprom
As for any other Zapi product it is possible to access memory cells inside the
RAM or inside the EEPROM of the console.
Select the menu to use depending on which memory cell must be read/written.
U These two menus are mainly used for debugging purposes or other special
tests. Use them only after receiving instructions from a Zapi technician.
6.3 Clear eeprom
Enter this menu to perform the CLEAR EEPROM operation as in any other Zapi
product. If EEPROM is cleared all console parameters will be reset to default
values except the real-time clock
.
Also the records of the SAVE function will be deleted.
Notice that the console will ask confirmation twice before performing this function.
6.4 Config rtc
The Smart Console has an internal real-time clock (RTC) which saves time and
date.
The RTC is powered by a separate button cell and it is independent of main
power sources of the console.
In this menu the RTC time and date can be set.

Other manuals for Zapi SMART CONSOLE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zapi SMART CONSOLE and is the answer not in the manual?

Zapi SMART CONSOLE Specifications

General IconGeneral
BrandZapi
ModelSMART CONSOLE
CategoryController
LanguageEnglish

Related product manuals