Gap and Index
Hole Sensing
Range
The sensor position is indicated by the green ar
-
row at the front of the label guide that is visible
with the print head open and media out. The
sensor can be moved by squeezing the two lock
-
ing tabs, located under the label guide, and slid
-
ing the sensor in or out. For proper sensing,
ensure that the sensor is aligned with the center
portion of the label or index hole/notch.
The following dimensions show the required
position of the index hole or notch on tag stock
for the printer to demonstrate sensor range.
Dimension Min. Max. Nominal
A .236" None .512"
B .079" .512" .118"
C .098" 1.520" N/A
Troubleshooting
A-10 980412-001 Rev.A
B
C
A
min. max.
Sensor
Adjustment
Range
Inside Edge
of Tag Stock
Tag Tear-away
.314 Nominal Sensor Location