P10-48 Mobile Printer CPCLProgramming Manual
BHT-BAUD Command Example
The following example sets BHT-IR communications to
use a baud rate of 19200 BPS and to strip spaces from
received data fields.
! DF AUTOEXEC.BAT
! UTILITIES
SRF-ACCESS
BHT-MODE STRIP-SPACES
BHT-BAUD 19200
END-SRF-ACCESS
PRINT
BHT-BAUD Command
This command will set both the IR and the cable transmit
speeds. You must insure that both the printer and the
BHT are set to this same baud rate. This can also be
changed in an AUTOEXEC.BAT file with the BHT-BAUD
<baud-rate> command.
Format:
{command} {baud rate}
where:
{command}: BHT-BAUD
{baud rate}: 9600,19200. Default value for Zebra
mobile printers is 9600 BPS.