P14-26 Mobile Printer CPCLProgramming Manual
continued on next page
media.tof
type: getvar; setvar
This parameter refers to the print’s top-of-form setting.
The TOF setting is used to program the distance between
the top-of-form and the end of the next (positive value) or
previous (negative value) eye-sense mark or gap. The
eye-sense-mark or gap that is closer to the top-of form
should be used for top-of-form setting. Refer to the SET-
TOF command in Section 9 for more detailed information
on the TOF setting.
getvar result Current top-of-form setting.
Example Description Get current top-of-form setting
Syntax ! U1 getvar “media.tof”
Result “0”
setvar choices “0” through “119”
Default “119”
Example Description This parameter sets the printers
top of form.
Syntax ! U1 setvar “media.tof” “119”
Result Printer will set top-of-form to 119.