25
D+ H/L
Connects to D+ signal at smart alternator.
If ACC or D+ signal is in high level, please connect to D+ H.
If D+ signal is in low level, please connect to D+ L.
When both alternator and auxiliary battery are well connected, the built in
booster charger will automatically judge if engine is turning on by detecting
D+ signal or sensing alternator output voltage, to decide to charge the battery
or not.
ACC/D+
Term
Configuration
Starter battery
voltage
Time delay
Default
Range
Default
Range
With ACC/D+
connected
ACC/D+ AND voltage
meets the threshold
13.2V
12~14.5V
20s
5~60s
Without ACC/D+
connected
voltage meets the
threshold
13.2V
12~14.5V
20s
5~60s
ACC+/D+
Term
Configuration
Starter battery
voltage
Time delay
Default
Range
Default
Range
With ACC/D+
connected
no ACC/D+ OR
voltage meets the
threshold
12.8V
11.6~13.5V
Immediately
/
Without
ACC/D+
connected
voltage meets the
threshold
12.8V
11.6~13.5V
60s
5~120s
Table 3-3 Charging logic for 12V system