7 FAQ
Type
Times
of ALM
light
flashes
Name
Processing suggestions
Fault
protection
1
Output short
circuit
protection
Please check that the 12V
Output or M12-100/P(M12-200/H)
positive and negative connections are not
reversed or short-circuited.
If there is no wiring error,
please contact your dealer.
2
Discharge
over current
protection
Check that the discharge
current of the ECO does not exceed the
rated discharge current, if it does, switch
off part of the load.
If the discharge current does
not exceed the rated discharge current,
please contact your dealer.
3
Charging
over current
protection
Please contact your dealer.
4
General low
voltage
protection
The battery capacity is already
low, please recharge the ECO
immediately.
5
Cell low
voltage
protection
The battery capacity is already
low, please recharge the ECO
immediately.
6
General high
voltage
protection
Please contact your dealer after
switching off the charger.
7
Cell high
voltage
protection
Please contact your dealer after
switching off the charger.