33
Type
Times
of ALM
light
flashes
Name
Processing suggestions
Fault
protection
8
Discharge
high
temperature
protection
Please check that the ambient
temperature at the ECO installation
location is not too high.
Please check that the wire diameter of
the ECO cable meets the requirements of
the manual.
Please check that the discharge current
and discharge time of the ECO do not
exceed the specified requirements.
If these are normal, please contact your
dealer.
9
Discharge
low
temperature
protection
Please check if the ambient temperature
at the ECO installation location is below -
20°C. If so, please connect the alternator
(grid) to 12V Input (230V Input) to raise
the temperature of the lithium battery
inside the ECO by heating the heating
film inside the ECO.
If this still does not solve the problem,
please contact your dealer.
10
Charging
high
temperature
protection
Please check that the ambient
temperature at the ECO installation
location is not too high.
If this is correct, please contact your
dealer.
11
Charging low
temperature
protection
Please check if the ambient temperature
at the ECO installation location is below
2°C. If so, please connect the
alternator(grid) to 12V Input(230V Input)
to raise the temperature of the lithium
battery inside the ECO by heating the
heating film inside the ECO;
If this still does not solve the problem,
please contact your dealer.
12
BMS circuit
high
temperature
protection
Check that the ambient temperature at
the ECO installation location is not too
high.
Please check that the discharge current
and discharge time of the ECO do not
exceed the specified requirements.
If the above is correct, please contact
your dealer.