125
ADDITIONAL WEIGHTS
MAXIMUM WEIGHT OF FLUID (kg) ACCORDING TO DIMENSIONS OF TYRES
Tyre dimensions 12,4-36 14,9-28 16,9-28 16,9-30 480/70R30 16,9-34 18,4-30 18,4-34
Weight (kg) 160 190 215 240 280 250 337 345
NON-FREEZING SOLUTION FOR FILLING OF TYRES
Water for prepa-
ration of solution
Calcium
chloride
CaCl
2
Lime
hydrate
Solution density
at 20 C
Solidification
point
approx.
Total
volume
Additional
weight
(l) (kg) (kg)
(C)
(l) (kg)
45 11,8 0,21 1,13 -18 50 57
45 13,9 0,23 1,18 -25 50 59
45 15,4 0,25 1,21 -30 50 61
Preparation of solution:
1. Anhydrous lime CaCl
2
shall be added to water, never inversely!
2. The fluid is not dangerous, however, handle with it carefully. Wash spilled drops with clean water.
3. Before filling let the solution cooled down. Observe the prescribed volume of hydrated lime.
4. The solution may not come into contact with metal parts and electric installation! It does not damage the tyre tube valve.
5. Frost-resistant solution, prepared in the given composition, may not be used in the cooling system!
6. Dispose anti-freeze means after discharging as special waste!