  • J
    joel98Sep 10, 2025
    What to do if Zeversolar Zeverlution 1500S shows error code 36?
    • K
      Kayla AcostaSep 10, 2025
      If your Zeversolar Inverter displays error code 36, ensure the grounding connection of the inverter is reliable. Perform a visual inspection of all PV cables and modules. If the fault is still present after these checks, contact the service.
  • A
    Ashley FordAug 22, 2025
    What to do if Zeversolar Inverter displays Presumable Fault 34?
    • A
      Amanda BaxterAug 22, 2025
      If your Zeversolar Inverter displays Presumable Fault 34, check the grid voltage and grid connection on the inverter. Also, check the grid voltage at the point of connection of the inverter. If the grid voltage is outside the permissible range due to local grid conditions, try modifying the values of the monitored operational limits after informing the electric utility company first. If the grid voltage is within the permitted range and the fault persists, contact service.
  • A
    Andrew KingAug 25, 2025
    What to do if Zeversolar Inverter shows Permanent Fault 1, 2, 3, 4, 5, 6, 8, 9?
    • M
      Miguel GrantAug 25, 2025
      If your Zeversolar Inverter is showing Permanent Fault 1, 2, 3, 4, 5, 6, 8, 9, disconnect the inverter from the utility grid and the PV arrays, and reconnect them after the display and LED turn off. If the fault continues to be displayed, contact the service.
  • K
    Kathryn RobertsAug 26, 2025
    What to do if Zeversolar Inverter shows Presumable Fault 41, 42, 43, 44, 45?
    • A
      Andrew ValentineAug 26, 2025
      If your Zeversolar Inverter is showing Presumable Fault 41, 42, 43, 44, or 45, disconnect the inverter from the grid and the PV arrays, then reconnect them after 3 minutes. If the fault continues to appear, contact the service.
  • L
    Lee AbbottAug 27, 2025
    What to do if Zeversolar Zeverlution 1500S shows Presumable Fault 38?
    • J
      jeffrey97Aug 27, 2025
      If your Zeversolar Inverter is showing Presumable Fault 38, check the PV array’s insulation to ground, ensuring that the insulation resistance to ground is greater than 1 MOhm. Otherwise, visually inspect all PV cables and modules. Also, ensure the grounding connection of the inverter is reliable. If the fault occurs often, contact the service.
  • H
    Heather CunninghamAug 29, 2025
    What to do if Zeversolar Zeverlution 1500S displays Presumable Fault 36?
    • C
      Chelsea SingletonAug 29, 2025
      If your Zeversolar Inverter displays Presumable Fault 36, ensure the grounding connection of the inverter is reliable. Then, perform a visual inspection of all PV cables and modules. If the fault persists, contact the service.
  • B
    Brandon ThomasSep 18, 2025
    What to do if Zeversolar Inverter displays error code 41, 42, 43, 44, 45, 47?
    • C
      Carla DavenportSep 18, 2025
      If your Zeversolar Inverter shows error codes 41, 42, 43, 44, 45, or 47, disconnect the inverter from both the grid and the PV array. Wait for 3 minutes, then reconnect. If the fault persists, contact the service.
  • E
    Erin BarnesSep 12, 2025
    What to do if Zeversolar Zeverlution 1500S Inverter shows error code 40?
    • R
      Ronald QuinnSep 12, 2025
      If your Zeversolar Inverter is showing error code 40, verify that the airflow to the heat sink is not blocked. Also, check to see if the ambient temperature around the inverter is too high.
  • C
    Christian MoodySep 8, 2025
    How to fix error code 38 on Zeversolar Zeverlution 1500S?
    • K
      Kara SheppardSep 8, 2025
      To address error code 38 on your Zeversolar Inverter, start by checking the PV array’s insulation to ground, ensuring it's greater than 1 MOhm. Perform a visual inspection of all PV cables and modules. Ensure the inverter's grounding connection is reliable. If the problem persists, contact the service.
  • J
    Jordan HernandezSep 5, 2025
    What to do if Zeversolar Inverter shows error code 35?
    • B
      Brandon HollandSep 5, 2025
      If your Zeversolar Inverter displays error code 35, inspect the fuse and the circuit breaker in the distribution box. Verify the grid voltage and usability. Also, check the AC cable and the grid connection on the inverter. If the error persists, it is recommended to contact the service.

Zeversolar Zeverlution 1500S Specifications

General IconGeneral
Rated Output Power1500 W
Max. DC Voltage550 V
Number of MPPTs1
Nominal AC Voltage230 V
AC Voltage Range180 V - 280 V
Nominal AC Frequency50 Hz / 60 Hz
European Efficiency96.5%
CoolingNatural Convection
Operating Temperature Range-25°C to +60°C
Ingress Protection (IP) RatingIP65
Maximum Input Current10 A
CommunicationRS485