Eversol TL1000-20/TL1500-20/TL2000-20/TL3000-20 Solar Inverters
01
REV
DAT E

Table of Contents

Questions and Answers

  • M
    Michelle ThompsonAug 14, 2025
    What to do if Zeversolar Eversol TL1000-20 Inverter shows Permanent Fault 1, 2, 3, 4, 8, 9?
    • G
      Gary HardingAug 14, 2025
      If your Zeversolar Inverter displays Permanent Fault 1, 2, 3, 4, 8, or 9, disconnect it from both the utility grid and the PV array. Wait for 3 minutes, then reconnect it. If the fault persists, it may require professional attention.
  • M
    Mary FowlerAug 17, 2025
    What to do if Zeversolar Eversol TL1000-20 displays Fault 41, 42, 43, 44, 45?
    • B
      Billy HuffmanAug 17, 2025
      If your Zeversolar Inverter is showing Fault 41, 42, 43, 44, or 45, disconnect it from both the grid and the PV array. Wait 3 minutes before reconnecting. If the fault continues to appear, the device may need servicing.
  • P
    Patricia HoltAug 21, 2025
    What to do if Zeversolar Eversol TL1000-20 Inverter shows Presumable Fault 35?
    • Z
      Zachary CarterAug 21, 2025
      If your Zeversolar Inverter shows Presumable Fault 35, check the fuse and the circuit breaker in the distribution box. Also, examine the grid voltage, grid usability, AC cable, and grid connection on the inverter. If the fault persists after these checks, it might require professional assistance.
  • W
    Wesley BrownAug 25, 2025
    Why Zeversolar Eversol TL1000-20 displays Presumable Fault 34?
    • A
      Andrea BergerAug 25, 2025
      If your Zeversolar Inverter displays Presumable Fault 34, check the grid voltage and the grid connection on the inverter itself. Also, check the grid voltage at the point where the inverter connects. If the grid voltage is outside the permissible range due to local grid conditions, try to modify the monitored operational limits after informing the electric utility company first. If the grid voltage remains within the permitted range and the fault continues, it may require professional assistance.
  • D
    Dr. Jeremy BrooksAug 27, 2025
    What to do if Zeversolar Eversol TL1000-20 displays Presumable Fault 33?
    • M
      Mr. Jamie PughAug 27, 2025
      If your Zeversolar Inverter displays Presumable Fault 33, check the grid frequency and how often major fluctuations occur. If the fault is due to frequent fluctuations, consider modifying the operating parameters, but only after informing the grid operator.
  • S
    Steven RamirezAug 30, 2025
    What to do if Zeversolar Eversol TL1000-20 Inverter displays Presumable Fault 38?
    • J
      Jacob MayAug 31, 2025
      If your Zeversolar Inverter is showing Presumable Fault 38, check the PV array’s insulation to ground, ensuring the insulation resistance is greater than 1 MOhm. Perform a visual inspection of all PV cables and modules. Ensure the inverter's grounding connection is reliable. If the fault occurs frequently, it may require professional assistance.
  • M
    Morgan WaltersSep 3, 2025
    How to fix Presumable Fault 36 on Zeversolar Eversol TL1000-20 Inverter?
    • A
      Ashley RileySep 3, 2025
      To address Presumable Fault 36 on your Zeversolar Inverter, first ensure the grounding connection of the inverter is reliable. Then, perform a visual inspection of all PV cables and modules. If the fault persists, it may require professional assistance.
  • J
    johnstonjustinSep 7, 2025
    What causes Presumable Fault 37 on Zeversolar Eversol TL1000-20 Inverter?
    • P
      preston97Sep 7, 2025
      If your Zeversolar Inverter displays Presumable Fault 37, check the open-circuit voltages of the strings to ensure they are below the inverter's maximum DC input voltage. If the input voltage is within the permitted range and the fault persists, it may require professional assistance.
  • S
    Sonia HernandezSep 10, 2025
    What causes Presumable Fault 6 on Zeversolar Inverter?
    • D
      Dennis SanchezSep 10, 2025
      If your Zeversolar Inverter displays Presumable Fault 6, check the open-circuit voltages of the strings to ensure it is below the maximum DC input voltage of the inverter. If the input voltage is within the permitted range and the fault still occurs, it may require professional assistance.

Zeversolar Eversol TL1000-20 Specifications

General IconGeneral
Max. DC Voltage550 V
Nominal AC Power1000 W
Nominal AC Voltage230 V
Dimensions310 x 251 x 162 mm
Weight6.5 kg
Protection DegreeIP65
Rated Power Output1000 W
Number of MPP Trackers1
Maximum Input Current10 A
Power Factor>0.99
THD<3%
Cooling MethodNatural Convection
Protection LevelIP65
Output Voltage Range180-280 V
Operating Temperature Range-25°C - +60°C