  • V
    Vincent WallaceSep 10, 2025
    What to do if Zeversolar Zeverlution 1000S Inverter shows error code 36?
    • R
      Robert SalazarSep 10, 2025
      If your Zeversolar Inverter displays error code 36, ensure the grounding connection of the inverter is reliable. Perform a visual inspection of all PV cables and modules. If the fault is still present after these checks, contact the service.
  • L
    Laurie MejiaAug 22, 2025
    What to do if Zeversolar Zeverlution 1000S Inverter displays Presumable Fault 34?
    • S
      Sarah HigginsAug 22, 2025
      If your Zeversolar Inverter displays Presumable Fault 34, check the grid voltage and grid connection on the inverter. Also, check the grid voltage at the point of connection of the inverter. If the grid voltage is outside the permissible range due to local grid conditions, try modifying the values of the monitored operational limits after informing the electric utility company first. If the grid voltage is within the permitted range and the fault persists, contact service.
  • C
    christianchristianAug 25, 2025
    What to do if Zeversolar Zeverlution 1000S shows Permanent Fault 1, 2, 3, 4, 5, 6, 8, 9?
    • D
      Daryl OnealAug 25, 2025
      If your Zeversolar Inverter is showing Permanent Fault 1, 2, 3, 4, 5, 6, 8, 9, disconnect the inverter from the utility grid and the PV arrays, and reconnect them after the display and LED turn off. If the fault continues to be displayed, contact the service.
  • P
    Paul DillonAug 26, 2025
    What to do if Zeversolar Inverter shows Presumable Fault 41, 42, 43, 44, 45?
    • P
      patricklambAug 27, 2025
      If your Zeversolar Inverter is showing Presumable Fault 41, 42, 43, 44, or 45, disconnect the inverter from the grid and the PV arrays, then reconnect them after 3 minutes. If the fault continues to appear, contact the service.
  • D
    donna47Aug 27, 2025
    What to do if Zeversolar Zeverlution 1000S shows Presumable Fault 38?
    • R
      Robert RyanAug 28, 2025
      If your Zeversolar Inverter is showing Presumable Fault 38, check the PV array’s insulation to ground, ensuring that the insulation resistance to ground is greater than 1 MOhm. Otherwise, visually inspect all PV cables and modules. Also, ensure the grounding connection of the inverter is reliable. If the fault occurs often, contact the service.
  • A
    Alexis FitzgeraldAug 29, 2025
    What to do if Zeversolar Zeverlution 1000S Inverter displays Presumable Fault 36?
    • A
      Anthony FisherAug 29, 2025
      If your Zeversolar Inverter displays Presumable Fault 36, ensure the grounding connection of the inverter is reliable. Then, perform a visual inspection of all PV cables and modules. If the fault persists, contact the service.
  • J
    Juan JensenSep 18, 2025
    What to do if Zeversolar Inverter displays error code 41, 42, 43, 44, 45, 47?
    • R
      Ronald ReidSep 18, 2025
      If your Zeversolar Inverter shows error codes 41, 42, 43, 44, 45, or 47, disconnect the inverter from both the grid and the PV array. Wait for 3 minutes, then reconnect. If the fault persists, contact the service.
  • S
    Steven GarciaSep 12, 2025
    What to do if Zeversolar Inverter shows error code 40?
    • J
      Julie ConnerSep 12, 2025
      If your Zeversolar Inverter is showing error code 40, verify that the airflow to the heat sink is not blocked. Also, check to see if the ambient temperature around the inverter is too high.
  • A
    Abigail SmithSep 8, 2025
    How to fix error code 38 on Zeversolar Inverter?
    • A
      Alicia NormanSep 8, 2025
      To address error code 38 on your Zeversolar Inverter, start by checking the PV array’s insulation to ground, ensuring it's greater than 1 MOhm. Perform a visual inspection of all PV cables and modules. Ensure the inverter's grounding connection is reliable. If the problem persists, contact the service.
  • N
    natashacoxSep 5, 2025
    What to do if Zeversolar Inverter shows error code 35?
    • L
      laurafischerSep 5, 2025
      If your Zeversolar Inverter displays error code 35, inspect the fuse and the circuit breaker in the distribution box. Verify the grid voltage and usability. Also, check the AC cable and the grid connection on the inverter. If the error persists, it is recommended to contact the service.

Zeversolar Zeverlution 1000S Specifications

General IconGeneral
Rated Output Power1000 W
Output Voltage230 V
Efficiency96.5%
Weight6.5 kg
CoolingNatural Convection
Protection ClassIP65
Max. AC Power1000 W
Max. Output Current4.35 A
Number of MPP Trackers1
Maximum Input Current10 A
Operating Temperature Range-25°C to +60°C
AC Output Frequency50 Hz

Related product manuals