EasyManuals Logo

Zeversolar Zeverlution 3680 Quick Installation Guide

Zeversolar Zeverlution 3680
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
I
n
1.
U
b
r
2.
H
3.
A
I
f
1.
L
Quic
k
Zever
l
532-
0
n
verte
r
W
1×
U
se a Φ10
m
r
acket to t
h
H
ang the in
v
A
ttach the
o
f
additiona
l
Figur
e
L
oosen the
Danger to li
f
Before perfo
k
Insta
l
l
ution 36
0
8111-0
3
W
all bracke
t
1×
m
m bit to d
r
h
e wall.
v
erter ont
o
o
uter fins
o
l
groundin
g
e
A
four scre
w
f
e due to hi
g
rming any w
o
l
lation
80/400
0
3
Mounting
accessory ki
t
1×
r
ill 2 holes
o
the wall
b
o
f heat sin
k
g
or equipo
t
F
w
s of the c
o
g
h voltages i
n
o
rk on the inv
e
Guide
0
/5000
t
DC pl
u
conne
c
2
×
at a depth
b
racket sli
g
k
to both si
d
t
ential bon
d
F
igure B
o
ver using
a
n
the inverte
e
rter, ensure
t
u
g
c
to
r
Seali
n
plu
g
2
×
of about 7
0
g
htly down
w
d
es of the
w
d
ing is req
u
a
TX25 scr
e
r
t
he DC switch
n
g
g
s
WiFi
a
op
t
×
1
0
mm, inse
r
w
ards.
w
all brack
e
u
ired, grou
n
e
wdriver a
n
& AC circuit b
a
ntenn
a
t
iona
l
c
o
×
r
t the wall
e
t using M
5
n
d the inve
r
nd remove
b
reaker are s
w
Smart mete
r
o
nnecto
r
opti
o
1×
anchors a
n
5
screws, a
r
ter as sho
w
the cover.
w
itched off an
d
www.ze
v
r
o
na
l
Doc
u
n
d attach t
h
s shown in
w
n in Figu
r
d
cannot be r
e
v
ersolar.c
u
mentatio
n
1
×
h
e wall
Figure A.
r
e B.
e
activated.
om
2
1. Zeve
r
the d
i
2. Zeve
r
all do
c
3. Zeve
r
4. Zeve
r
applic
a
5. PV m
6. Whe
n
condu
c
can le
a
7. All c
o
8. Zeve
r
Zeve
r
The i
n
coun
t
Icon
- Mount
t
- Ensure
- Ambie
n
- Install
t
- Ensure
the inv
e
- The m
o
inverte
r
- If mou
n
a solid
s
recom
m
- Do not
- Mount
t
- The el
e
- Obser
v
or obj
e
2. AC c
a
3. Inser
t
ferrul
e
the co
n
4. Thre
a
diame
t
5. Inser
t
Blad
e
6. Tight
e
7. Secu
r
1. DC c
a
2. Lead
Pres
s
Push t
h
2.0N
m
Conne
c
3. For u
Inser
t
Final
l
Danger
When
e
compo
n
the DC
c
•Do not
•Do not
•Do not
•Do not
•Have t
h
•If an e
r
•Before
Reco
m
r
lution is a
t
i
rect curre
n
r
lution mu
s
c
umentatio
n
r
lution is s
u
r
lution mu
s
a
tion class
odules wit
h
n
exposed t
o
c
tors and t
h
a
d to lethal
o
mponents
r
lution com
r
lution also
n
verter lab
e
t
ries and re
g
Ex
p
Ge
n
- i
m
Ha
z
Ho
t
t
he inverte
good acce
n
t tempera
t
t
he inverte
optimum
o
e
rter to dir
e
o
unting me
t
r
's weight
a
n
ted in a re
s
s
urface, pl
a
m
ended du
e
put any ob
t
he inverte
e
ctrical con
v
e the reco
m
e
cts as fol
l
a
ble requir
e
t
the cond
u
e
acc. to
D
n
tact.
a
d the AC
c
t
er over 12
m
t
the PE, N
a
e
5.5, tor
q
e
n the swi
v
r
e the cov
e
a
ble requir
e
the stripp
e
s
the clam
p
h
e swivel
n
m
).
c
t the asse
nused DC
c
t
the sealin
l
y insert th
e
to life due to
e
xposed to su
n
n
ents of the i
n
c
onnectors fr
disconnect t
h
touch non-in
s
touch the DC
touch any liv
e
h
e inverter m
o
r
ror occurs, h
a
connecting t
h
Direction
m
mended cl
e
t
ransform
e
n
t of the P
V
s
t only be
o
n
relating
t
u
itable for
i
s
t only be
o
A. Do not
c
h
a high ca
p
o
sunlight,
t
h
e live com
electric sh
o
must rem
a
plies with t
complies
w
e
ls with th
e
g
ions, plea
s
p
lanation
n
eral warn
m
portant s
a
z
ardous v
o
t
surfaces
r in areas
w
ss to the i
n
t
ure shoul
d
r in an envi
o
peration a
e
ct sunligh
t
t
hod, locat
a
nd dimen
s
s
idential a
r
a
sterboar
d
e
to audibl
e
jects on th
e
r verticall
y
nection ar
e
m
mended
c
l
ows to en
s
e
ments as
f
u
ctor into
t
D
IN 46228
c
able throu
m
m.
a
nd L cond
u
q
ue: 1.2Nm)
v
el nut of t
h
e
r in the se
q
e
ments as
f
e
d cable all
p
ing bracke
t
n
ut up to t
h
mbled DC
p
c
onnectors
g plug into
e
DC plug
c
high voltages
n
light, the PV
a
n
verter. Touc
h
om the invert
h
e DC connec
t
s
ulated cable
e
conductors.
e
component
s
o
unted, instal
l
a
ve it rectified
h
e PV array, e
e
arance
3
e
rless pho
t
V
array int
o
o
perated b
y
t
o its instal
l
i
ndoor and
o
perated w
i
c
onnect an
y
p
acity to gr
o
t
he PV arr
a
ponents of
o
cks.
a
in within th
he Low-Vo
w
ith the re
q
e
CE mark a
n
s
e visit we
b
ing
a
fety infor
m
o
ltage
w
here it ca
n
n
verter for
d
be
40°
C
ronment
w
nd extend
s
t
, rain and
s
i
on and su
r
s
ions.
r
ea, we rec
o
d
and simil
a
e
vibration
s
e
inverter.
y
or tilted
b
e
a must po
i
c
learances
s
ure suffici
f
ollows:
t
he suitabl
e
and crim
p
gh the cab
u
ctors to t
h
. The assig
n
h
e cable gl
a
q
uence 1 to
f
ollow:
the way in
t
down unt
h
e thread a
n
p
lug conne
c
,
push dow
the DC plu
c
onnectors
of the PV arr
a
a
rray genera
t
h
ing the DC co
er under load
t
ors under lo
a
e
nds.
s
of the invert
l
ed and com
m
by qualified
p
nsure that th
e
above
3
00mm
t
ovoltaic (
P
o
grid-com
p
y
qualified
p
l
ation, co
m
outdoor u
s
i
th PV arra
y
y
sources
o
o
und must
b
a
y generat
e
the invert
e
eir permitt
e
ltage Direc
t
q
uirements
n
d RCM m
a
b
site (
ww
w
m
ation
n
not be to
u
installatio
n
C
to ensure
w
ith good v
e
s
ervice lif
e
s
now.
r
face must
o
mmend
m
a
r material
s
s
when in u
s
Do not co
v
b
ackward b
y
i
nt downw
a
to walls,
o
ent heat di
s
e
p
le gland. P
h
e screw te
r
n
ment is ac
a
nd by usi
n
4 (screwd
to the DC
p
il it audibl
y
n
d tighten
(
c
tors to th
e
n the clam
g connect
o
with seali
n
Objec
t
A
B
C
D
The PE i
ay
t
es dangerou
s
nductors or t
h
, an electric a
r
a
d.
er.
m
issioned onl
y
p
ersons only.
e
DC switch is
belo
w
500mm
P
V) inverte
r
p
liant alter
p
ersons wi
t
m
missionin
g
s
e.
y
s of prot
e
o
f energy
o
b
e used if t
h
e
s dangero
u
e
r. Touchin
g
e
d operati
n
t
ive 2014/
3
of safety a
a
r
k
. For mo
r
w
.zeverso
l
Icon
u
ched inad
v
n
and possi
optimal o
p
e
ntilation.
e
by avoidi
n
be suitabl
e
m
ounting t
h
s
are not
s
e.
v
er the inv
e
y
max. 15°
a
rds.
o
ther inver
t
s
sipation.
lease take
r
minal blo
c
cording to
t
n
g a torque
river type:
p
lug conne
c
y
snaps int
o
(
SW15, tor
q
e
inverter.
ping brack
e
o
r, tighten
t
n
g plugs in
t
Description
External dia
m
Conductor cr
o
Stripping len
g
Stripping len
g
nsulated con
d
s
DC voltage
w
h
e live comp
o
r
c may occur
y
by qualified
p
switched off
a
sides
200mm
r
with two
nating cur
r
t
h the app
r
g
, operatio
n
e
ction clas
s
o
ther than
P
h
eir coupli
n
u
s DC volta
g
g
the DC co
n
n
g ranges a
t
3
5/EU and t
nd EMC in
A
r
e informa
t
l
ar.com
).
v
ertently.
ble servic
e
p
eration.
n
g exposin
g
e
for the
h
e inverter
o
e
rter.
t
ers,
out the se
a
c
ks and tigh
t
he symbo
l
of 3.5Nm.
T25,torqu
e
c
tor.
o
place.
q
ue:
e
t and pus
h
t
he swivel
n
t
o the corr
e
m
ete
r
o
ss
-
section
g
th of the ins
u
g
th of the out
e
d
uctor must
b
w
hich is prese
n
o
nents can le
a
leading to el
e
p
ersons with
t
a
nd it cannot
b
MPP track
e
r
ent, and f
e
r
opriate ski
n
and main
t
s
II in accor
d
P
V module
s
n
g capacity
g
e which is
n
ductors o
r
t
all times.
he EMC Dir
e
A
ustralia a
n
t
ion about
c
Explan
Time n
energ
y
WEEE
d
Obser
v
e
.
g
o
n
al
ring inser
t
ten them (
s
l
on the cir
c
e
: 2.5Nm).
h
the swive
n
ut (torqu
e
e
sponding
D
u
lated conduc
t
e
r sheath of t
h
b
e 5mm long
e
n
t in the DC c
o
a
d to lethal el
e
e
ctric shock a
n
t
he appropria
t
b
e reactivate
d
e
rs which
c
e
eds it into
lls who ha
v
t
enance.
d
ance with
s
to the inv
does not e
x
present in
t
r
the live c
o
e
ctive 201
4
n
d New Zea
l
c
ertificates
ation
eed to dis
c
y
d
esignatio
n
v
e the doc
u
t
when the
s
crewdrive
r
c
uit board.
l nut up to
e
: 2.0Nm).
D
C inputs
o
t
ors
h
e AC cabl
e
e
r than the L a
o
nductors an
d
e
ctric shocks.
n
d burns.
t
e skills.
d
.
c
onverts
the utility
g
v
e already
IEC 61730
,
v
erter.
x
ceed 1.0μ
t
he DC
o
mponents
4
/30/EU.
l
and mark
e
in other
c
harge sto
r
n
u
mentation
e
cable ext
e
r
type:
the thread
o
n the inve
r
Valu
e
9 mm to 14
4 mm² to 6
approx. 12
m
approx. 70
m
a
nd N conduct
o
d
the live
If you discon
n
g
rid.
read
,
F.
e
ts.
r
ed
e
rnal-
.
r
ter.
mm
mm
²
m
m
m
m
o
rs
n
ect
3
1
All manuals and user guides at all-guides.com
all-guides.com

Other manuals for Zeversolar Zeverlution 3680

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zeversolar Zeverlution 3680 and is the answer not in the manual?

Zeversolar Zeverlution 3680 Specifications

General IconGeneral
BrandZeversolar
ModelZeverlution 3680
CategoryInverter
LanguageEnglish

Related product manuals