9.2.1.5 Electrical connection
The connection of the bus cable takes place at the slot X-CAN of the frequency inverter.
X-CAN
CL
CH
0VC
CAN High (H)
CAN Low (L)
GND
(1)
(2)
(3)
(4)
Optionaler
Schirmanschluss
Connection CAN
9.2.1.6 Activating the interface
The activation of the CAN interface can be set in the menu Control system/CONFIG.
Control
|
-
" CONFIG 01:BP_DCP1
|
-
" 02:BP_DCP2
Conguration
The INFO menu shows CAN information at the pages 14 - 17 (Assumption: "CONFIG" = "02:
ZA_CAN").
9.2.1.7 Operation modes
Information
For the ZETADYN 3 are two operation modes by using CAN:
Velocity Mode (Velocity Mode [pv])
Velocity Mode
Original operating instructions
ZETADYN 3C Serial communication
R-TBA08_03-GB 1619 Part.-No. 00163322-GB