26
Installation instructions
805845UK V1.02 July 2018 - G4 Command Centre
Technical support
Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk
Note When removing hose, take care not to
lose plastic olive from the fitting.
After replacing a cylinder or
after making a gas connection,
perform a leak test to check for gas leaks
between regulator and cylinder, and between regulator and
braided hose.
Stage 1
Turn the gas off.
Using soapy water applied with a sponge, or with a
brush, cover all of the gas joints with a liberal
amount of suds.
Stage 2
Turn the gas on.
Inspect the joints for leaks.
If any bubbles appear to grow, the joint will need to be
resealed and tested again.