Installation instructions
805845UK v1.02 July 2018 - G4 Command Centre
Technical support
Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk
6.1 Description
The carbonation valve has been designed to provide the installer with the ability to preset the level of
carbonation of the sparkling water, to the taste of the user. The carbonation valve can be tted at the time of
installation, or retrotted to G4 Command Centres previously installed.
6.2 Installation
Attach the carbonation valve to the Command Centre
using the 1/4” plastic tubing.
Attach the sparkling pipe to the outlet .
water ow
Adjustment
Inlet
Outlet
+
-
6.3 Adjustment
The carbonation valve has an adjustable ow rate. The optimum setting for the valve is 1.6 litres/minute. Use a
6mm Allen key or large at blade screwdriver to adjust the ow rate of the valve.
To adjust the ow rate rotate the screw anti clockwise. Fitting this valve should reduce the splatter or spitting
of the sparkling water out of the tap. It should also produce more visible bubbles in the water. To measure
the ow rate, use a measuring cup and run the sparkling water for 15 secs. Multiply the amount of water
dispensed by 4 to get the ow rate per minute.
1.6litres/min. is the optimum ow rate.
If the ow rate is adjusted too high,
the carbonation can will be emptied
of water, leaving only CO2 to be
dispensed from the tap.