6.1 Description
The carbonation valve has been designed to provide the installer with the ability to preset the level of
carbonation of the sparkling water, to the taste of the user. The carbonation valve can be tted at the time of
installation, or retrotted to G4 Command Centres previously installed.
6.2 Installation
• Attach the carbonation valve to the Command Centre
using the 1/4” plastic tubing.
• Attach the sparkling pipe to the outlet .
water ow
Adjustment
Inlet
Outlet
+
-
6.3 Adjustment
The carbonation valve has an adjustable ow rate. The optimum setting for the valve is 1.6 litres/minute. Use a
6mm Allen key or large at blade screwdriver to adjust the ow rate of the valve.
To adjust the ow rate rotate the screw anti clockwise. Fitting this valve should reduce the splatter or spitting
of the sparkling water out of the tap. It should also produce more visible bubbles in the water. To measure
the ow rate, use a measuring cup and run the sparkling water for 15 secs. Multiply the amount of water
dispensed by 4 to get the ow rate per minute.
1.6litres/min. is the optimum ow rate.
If the ow rate is adjusted too high,
the carbonation can will be emptied
of water, leaving only CO2 to be
dispensed from the tap.
Section 6 Carbonation valve installation
• Fitted in sparkling systems only