6 807066 v1.01 08.21 HBP AB 21 Install Instructions
TECHNICAL SPECIFICATION
Tank
size
(litres)
Heat up
time
(Inlet
15°C)
Heat up
time
(Inlet
10°C)
Rated voltage and power
Dimensions
W x D x H
(mm)*
Filled
weight
(kg)
3.0 16mins 17mins
220-240V, 50Hz, 1500W (AU/NZ)
220-240V, 50Hz, 1400W (non-AU/NZ)
220V, 60Hz, 1250W
300 x 183 x 439 12
5.0 16mins 17mins
220-240V, 50Hz, 2200W
220V, 60Hz, 2000W
329 x 201 x 473 15
7.5 23mins 23mins 329 x 201 x 586 20
15.0 40mins 43mins
220-240V, 50Hz, 2400W
401 x 301 x 606 33
25.0 47mins 50mins 401 x 301 x 786 47
40.0 60mins 64mins
220V, 50Hz, 6000W
415V, 50Hz, 6000W
526 x 286 x 847 70
* add 28mm to Depth for Fascia (Hydroboil Plus)
add 98mm to Depth for Tap and Fascia (Autoboil)
Before installation, ensure that:
All technical specifications and instructions have been reviewed and understood.
The mounting wall can support the product weight when full of water. See Technical
specifications.
Sufficient space is provided to install the appliance and other components in accordance
with these installation instructions. Check cable and plumbing against inlet /outlet
positions before proceeding.
An easily accessible socket and double pole isolation switch (correctly rated for the
appliance) is required. For models rated below 3kW: 220-240V AC 50-60Hz; for models
rated above 3kW: 380-415V AC mains power.
The appliance must be connected to a potable water supply with working pressure of: AU/
NZ 150 - 700 kPa (1.5 - 7.0 bar); UK 70 - 500 kPa (0.7 - 5.0 bar).
The appliance must be connected with an isolating valve within reach of the hose and
positioned so that the valve will not be obstructed.
A 350 kPa (3.5 bar) pressure limiting valve (not supplied) must be fitted if the incoming
mains water pressure is likely to exceed 500 kPa (5.0 bar)
The appliance must be placed upright with its base in a horizontal position.
IMPORTANT! Do not proceed with the installation if these
requirements are not met.
!