Page 5 of 12 Zip Hydroboil - Installation & Operating Instructions - 85264 - May 2013 v1.01
Installation Requirements
Beforeinstalling,ensurethatthefollowingareavailable:
a. Sufficientspacetopositiontheheatersothereisatleast150mmclearanceabovetheheaterforserviceaccess,
65mmtoitsleftand20mmtoitsrightthetapoutletusuallyshouldbepositionedatleast200mmaboveadraining
board or drip tray.
Read These Warnings First Continued
Safety
Thisapplianceisnotintendedforusebypersons(includingchildren)withreducedphysicalsensoryor
mentalcapabilities,orlackofexperienceandknowledgeunlesstheyhavebeengivensupervisionor
instruction concerning use of the appliance by a person responsible for their safety. Children should be
supervisedtoensurethattheydonotplaywiththeappliance.
Pleasereadallinstallationrequirements,installationproceduresandprecautionsbeforeinstallingany
ZipHydroboilinstantboilingwaterheater.
NeverattempttoinstallanyZipHydroboilinstantboilingwaterheaterwithoutreadingalloftheapplicableinstructions.
Careshouldbetakentoavoidtouchingthemetalbodyofthetapwhichcanbecomeveryhot.
InsomehardwaterareaswheremineralscaleaccumulationintheboilingchamberoftheZipHydroboilmaybecome
aproblem,considerationshouldbegiventothemaintenancerequired.Asuitableformofwatertreatmentmaybe
necessary.
Astheinstaller,itisyourresponsibilitytosupply(ifnecessary)andinstallallvalvesasrequiredbylocalregulationsand
relevant standards.
TheplumbinginstallationmustbedoneinaccordancewithlocalWaterAuthorityregulationsandtheseInstallation
Instructions.
This appliance must be earthed.
Ifthepowercableisdamageditmustberepairedonlybyaqualifiedtechnician.Toavoidhazards,allinstallation
proceduresmustbecarriedoutbyasuitablyqualifiedtradesperson.Thepowercableandpoweroutletmustbeinasafe
visible position for connection.
Thepowercablemustbeadequatelysecured.
Donotremovethecoveroftheheaterunderanycircumstanceswithoutfirstisolatingtheheaterfromthepowersupply.
Theappliance,itswiringandpipingmustnotbemodiedinanyway.
Theappliancemustbecompletelylledwithwaterbeforebeingswitchedon.
Incaseofmalfunctionisolatethepowersupplyimmediately.Incaseofleaksalsoisolatethewatersupply.Repairsmust
onlybecarriedoutbyZipHeaters(UK)LtdoranauthorisedZipserviceengineer.
Lifting
TakecarewhenliftingtheZipHydroboilunit.Someunitsmayexceedsafeliftinglimits.Ifyoufeelthisisbeyondyour
personalcapabilities,pleaseseekassistancewiththelift.Seespecificationsonpage4forweights.
Operating Conditions:
Theambienttemperaturesthisunitshouldoperatewithinis5ºC-50ºC.
Frostprotection:Ifthisheaterislocatedwhereambientairtemperaturecouldfallbelow5ºC;whentheheaterisnotin
use,donotturnofftheapplianceelectrically.Thissafeguardwillprotecttheunitfromfrostdamagebutdoesnotoffer
thesameprotectiontotheconnectingpipeworkandfittings.
Thisheaterisintendedonlyforindooruseandshouldneverbeinstalledoutdoorsorbeexposedtotheelementsofnature.
Thisunitmustnotbepositionedinanareathatmaybecleanedbyawaterjet.Thisunitmustnotbecleanedbyawaterjet.
Cleaning:
Hydroboil should only be wiped clean with a damp cloth. Never use abrasive cleaning agents or solvents on any
part of the Hydroboil, particularly the tap.