802265US v1.27 06.21 BCS, BCS100-75 Install Instructions Page 17 of 36
4.3 Hose and tube fitting
Remove all caps from the top of the Command Center
(except the mixer caps)
Only remove the mixer caps if a mixer faucet is to be
fitted.
Fit the foam insulation to the Blue and to the White tubes
after trimming them to length
Install the mains water braided hoses to the Command
Center before locating the unit in place.
NOTE: Do not overtighten
Connector + Strainer
90° Bend end
of Braided Hose
To HydroTap
Command Centre
Braided hose for
Mains Water Supply
From Mains
Water Supply
Installation Instructions
John Guest fittings (Insertion and removal)
Be careful when cutting the poly tube so that there are no rough
edges and that the tube is not distorted.
1. Use a sharp knife to ensure the tube has a clean, straight
edge. Do not cut at an angle.
2. Remove any swarf or unwanted material.
3. Push the tube into the John Guest fitting making sure all
connections to the John Guest fittings are pushed in past
the “O” ring to full depth, at least 15mm (⅝”).
4. Check for a good joint by pulling back on the tube. If the
tube comes out, of the fitting, repeat the above step.
5. To remove the tube, press the collet into the fitting and at
the same time pull back on the tube.
4.4 Installing carbonation valve
1. Connect the white tube for sparkling water from the faucet
to the outlet of the carbonation valve.
2. Connect the white tube from the inlet of the carbonation
valve to the Sparkling Outlet connection on top of the Com-
mand Center, as shown in the following Sections.
3. The carbonation valve has an adjustable ow rate. The op-
timum setting for the valve is 1.6L (0.4 gallons) per minute.
Using a 6mm (¼”) Allen key or a large at blade screw driv-
er, you can adjust the ow on the valve. See section 5.7 for
carbonation valve ow rate adjustment.
To faucet