SECTION 4: Technical data
Water supply pressure requirements
A pressure limiting valve must be fitted for mains water pressures
above the maximum limits stated above in accordance with local
plumbing regulations.
Note: All models (excluding UK) have an internal pressure limiting device
to reduce the maximum mains regulated pressure (700kPa in Australia),
protecting the system against pressure surges above 500kPa.
Component
Min - Max pressure, kPA (bar)
Australia UK
HydroTap 170 (1.7) - 700 (7.0) 170 (1.7) - 500 (5.0)
Sparkling HydroTap 250 (2.5 ) - 700 (7.0) 250 (2.5) - 500 (5.0)
Vented Mixer Tap 300 (3.0) - 700 (7.0) 200 (2.0) - 500 (5.0)
Booster 200 (2.0) - 700 (7.0) 200 (2.0) - 500 (5.0)
Limescale filter 200 (2.0) - 700 (7.0) 200 (2.0) - 500 (5.0)
Electricity supply requirements
220-240V 50Hz AC (for power requirement see table above).
Booster specification
Specification Rating
Power 230V 50/60Hz 2.20kW
Power 240V 50/60Hz 2.40kW
Flow rate 1.2 L/min
Without booster With booster
Australia 1x 220 - 240V AC 10A socket 2x 220 - 240V AC 10A sockets
UK 1x 220 - 240V AC 13A socket 2x 220 - 240V AC 13A sockets
Water supply connection
1/2” BSP (G1/2)