EasyManuals Logo

ZKTeco Notus Quick Start Guide

ZKTeco Notus
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
Lock Relay Connection
The system supports Normally Opened Lock and Normally Closed
Lock.
The NO LOCK (normally opened at power on) is connected with 'NO1'
and 'COM' terminals, and the NC LOCK (normally closed at power on)
is connected with 'NC1' and 'COM' terminals. Take NC Lock as an
example below:
AUX
AL+
AL-
NC
COM
NO
BUT
GND
BELL+
BELL-
GND
SEN
AUX
AL+
AL-
NC
COM
NO
BUT
GND
BELL+
BELL-
GND
SEN
AUX
AL+
AL-
NC
COM
NO
BUT
GND
BELL+
BELL-
GND
SEN
Door Sensor, Exit Button & Alarm Connection
Door Sensor
Alarm
-
+
-
+
-
+
Detector
Power
Smoke Detector
Exit Button
Alarm Power
3
NO
COM