1
CONTENTS
1 General.................................................. 2
1.1 General terms of delivery..............................2
1.2 Voltage.......................................................... 2
1.3 Water treatment.............................................2
2 Description............................................ 2
2.1 Presentation................................................... 2
2.1.1 Edenpac 2, 3, 4 and 5
2.1.2 Edenpac 6
2.2 Dimensional characteristics........................... 5
2.2.1 Edenpac 2,3, 4 and 5
2.2.2 Edenpac 6
3 Installation............................................ 7
4 Connections .......................................... 9
4.1 Access to the electrical card .............................9
4.1.1 Edenpac with single fan
4.1.2 Edenpac with double fan
4.2 Hydraulic connections......................................10
4.3 Electric connection...........................................11
5 Regulator operation............................. 12
5.1 Presentation ...................................................... 12
5.2 Setting the target temperature...........................12
6 Starting up............................................ 13
6.1 Check................................................................13
6.2 Start up the heat pump...................................... 14
6.3 Checking...........................................................14
6.4 Fault and state display ......................................15
6.5 Winter storage .................................................. 16
7 Maintenance instructions.................... 16
8 Recycling the product.......................... 16
9 Electrical diagrams.............................. 17
9.1 Electrical diagram of connection
Interface card.................................................... 17
9.2 Electrical diagram EdenPAC single-phase.......18
9.3 Electrical diagram EdenPAC three-phase.........19

Other manuals for Zodiac Edenpac 5

Questions and Answers

  • H
    Hannah MartinAug 17, 2025
    What causes high or low pressure fault in the refrigerating circuit of a Zodiac Heat Pump?
    • D
      Diana ParksAug 17, 2025
      A high or low pressure fault in the refrigerating circuit of your Zodiac Heat Pump can occur due to: * A mixture of water and air passing through the appliance. In this case, purge the hydraulic circuit. * Refrigerant overload. Consult a ZPCE-approved technician to check the refrigerant level. * Insufficient refrigerant. Consult a ZPCE-approved technician to look for leaks and refill refrigerant.
  • C
    castromichaelAug 19, 2025
    What causes a high pressure fault in the refrigerating circuit of a Zodiac Heat Pump?
    • M
      Mark TravisAug 19, 2025
      A high-pressure fault in the refrigerating circuit of your Zodiac Heat Pump may be due to: * Water and air mixture passing through the appliance. To resolve this, purge the hydraulic circuit. * Refrigerant overload. Consult a ZPCE-approved technician to check the refrigerant level.
  • A
    Amy DoyleAug 22, 2025
    What causes a low pressure fault in the refrigerating circuit of a Zodiac Edenpac 5 Heat Pump?
    • E
      Erin GloverAug 22, 2025
      A low pressure fault in the refrigerating circuit of your Zodiac Heat Pump is caused by insufficient refrigerant. To resolve this, consult a ZPCE-approved technician to look for leaks and refill refrigerant.
  • S
    Samantha MeyerAug 26, 2025
    What causes a voltage error on my Zodiac Edenpac 5?
    • P
      phillipsnancyAug 26, 2025
      A voltage error on your Zodiac Heat Pump indicates insufficient network power. Check the main power line and consult with the electrical network supplier.
  • A
    Allen GarciaAug 28, 2025
    What causes a phase order fault on a Zodiac three-phase heat pump?
    • M
      martinezreneeAug 28, 2025
      A phase order fault on your Zodiac three-phase heat pump can happen if: * There's incorrect wiring at the unit supply terminals. Check the wiring. * The electrical supplier modified the phase order. Contact your local electricity supplier. * There's a temporary failure of one or several phases.
  • D
    David ThomasAug 30, 2025
    Why does the anti-frost safety trigger on my Zodiac Edenpac 5 Heat Pump?
    • K
      Kathryn RussoAug 30, 2025
      The anti-frost safety on your Zodiac Heat Pump may trigger if the outside temperature is too low (below +5°C). Wait for a natural rise in the outside temperature.
  • J
    Justin PetersSep 2, 2025
    What does a control sensor fault mean on my Zodiac Edenpac 5 Heat Pump?
    • N
      nelsongarySep 2, 2025
      A control sensor fault in your Zodiac Heat Pump means the sensor is either defective or disconnected. Replace or reconnect the sensor.
  • S
    Shane LiSep 4, 2025
    What does an anti-frost sensor fault mean on my Zodiac Heat Pump?
    • A
      Alexandra HughesSep 5, 2025
      An anti-frost sensor fault on your Zodiac Heat Pump means the sensor is either defective or disconnected. To fix this, replace or reconnect the sensor.
  • B
    Brooke MillerSep 7, 2025
    What does a defrost sensor fault mean on my Zodiac Edenpac 5?
    • L
      Lynn WilliamsSep 7, 2025
      A defrost sensor fault on your Zodiac Heat Pump indicates that the sensor is either defective or disconnected. Replace or reconnect the sensor.
  • J
    Jennifer AllenSep 10, 2025
    Why is the anti-frost protection heater on my Zodiac Edenpac 5 activated?
    • G
      Gregory GuerraSep 12, 2025
      The anti-frost protection heater on your Zodiac Heat Pump activates when the outside temperature is too low (below +3°C) and the compressor is OFF. Wait for a natural rise in the outside temperature.

Summary

1. GENERAL

1.1 General terms of delivery

Details terms of delivery, risk, and storage procedures.

2.2 Dimensional characteristics

3. INSTALLATION

Installation site criteria

Outlines essential criteria for selecting an appropriate and safe installation location.

4. CONNECTIONS

4.3 Electric connection

Covers power supply requirements, cable specifications, and electrical protection measures.

5. REGULATOR OPERATION

6. STARTING UP

6.2 Start up the heat pump

A detailed procedure for initiating the heat pump's operation.

6.4 Fault and state display

Explains fault and status messages, their causes, and recommended actions.

6.4.1 Faults

Details fault messages, their causes, remedies, and associated alarms.

7. MAINTENANCE INSTRUCTIONS

Tasks for qualified personnel

Lists essential annual maintenance tasks to be performed by certified professionals.

9. ELECTRICAL DIAGRAMS

9.2 Electrical diagram EdenPAC single-phase

Detailed electrical diagram for single-phase EdenPAC heat pump models.

9.3 Electrical diagram EdenPAC three-phase

Detailed electrical diagram for three-phase EdenPAC heat pump models.

Zodiac Edenpac 5 Specifications

General IconGeneral
ModelEdenpac 5
CategoryHeat Pump
Heating Capacity5 kW
Cooling Capacity5 kW
Coefficient of Performance (COP)4.0
RefrigerantR410A