Instruc ons for installa on and use - English
Salt water chlorinator
Transla on of the original instruc ons in french
EN

Questions and Answers

  • E
    evanssusanAug 7, 2025
    What to do if my Zodiac Control Unit shows a 'NO FLOW' error?
    • S
      Shelley CherryAug 7, 2025
      If your Zodiac Control Unit displays 'NO FLOW,' it could be due to several reasons. The filtering pump may have stopped or failed, there might be air or gas in the cell, or the by-pass valves might be closed. Start by checking the pump, its programming clock, the filter, the skimmer(s), and the by-pass valves, and clean them if needed. Also, check the cable connections for the cell and flow controller. If necessary, replace the flow controller.
  • A
    amber92Aug 12, 2025
    Why does my Zodiac Control Unit say 'CHECK SALT'?
    • M
      michellewalkerAug 12, 2025
      If your Zodiac Control Unit displays 'CHECK SALT', it could be due to a few reasons. It could be due to lack of salt (less than 3g/L) because of water loss or dilution. Add salt to the pool to maintain a level of 4 g/L. Also, if the pool water temperature is too low (less than 18°C), reduce chlorine production or add salt to compensate. Lastly, the cell might be scaled up or worn, in which case you should clean or replace it.
  • P
    Patricia LoganAug 17, 2025
    What does 'OUTPUT FAULT' mean on my Zodiac Control Unit?
    • J
      Jasmine HarrisonAug 17, 2025
      If your Zodiac Control Unit displays 'OUTPUT FAULT', it could be due to a short-circuit in the cell or a disconnected/badly connected cable. Begin by checking the cell connections. It could also be due to a worn electrode, in which case you should replace the cell. In some cases, it could be due to insufficient salt. If necessary, have the control box (electronic board and transformer) checked by a qualified technician.
  • A
    Anthony MillerAug 22, 2025
    How to fix 'HIGH SALT' error on Zodiac Control Unit?
    • S
      Samantha HerreraAug 22, 2025
      If your Zodiac Control Unit indicates 'HIGH SALT', it means the salt level is too high (over 10 g/L). To fix this, you will need to drain part of the pool water to lower the salt concentration.
  • A
    Allison PhillipsAug 27, 2025
    What does 'FLASH' mean on my Zodiac Control Unit?
    • M
      Mark ShermanAug 27, 2025
      If your Zodiac Control Unit displays 'FLASH', wait about 10 minutes. Chlorine production should resume automatically at the previously set level.
  • R
    Ryan HayesSep 1, 2025
    Why does my Zodiac Control Unit keep losing the time setting?
    • G
      Gabriel MorrisonSep 1, 2025
      If your Zodiac Control Unit is losing the time setting, the accumulator is likely worn or defective. Check the condition of the accumulator and replace it if needed with a 3V accumulator, type "CR2032".

Summary

Safety and Recycling Information

General and Electrical Safety Warnings

Essential safety precautions for appliance operation, covering general and electrical hazards.

Installation - Part 1

Control Box Mounting

Guidelines for mounting and positioning the control box safely and correctly.

Installation - Part 2

Cell Installation Steps

Instructions for mounting the electrolysis cell on the pool piping, ensuring correct orientation and flow.

Installation - Part 3

Flow Controller Installation (Ei² Expert)

Steps for installing the flow controller, ensuring correct placement relative to the cell.

Electrical Connection Guide

Guidance on connecting the control box to the power supply and pool filtration pump.

Installation and Operation Setup

Ei² Expert User Interface

Using the Ei² Expert - Time and Modes

Using the Ei² Expert - Configuration

Maintenance Procedures

Electrode Cleaning Instructions

Step-by-step guide for cleaning the electrolyser cell's electrodes.

Troubleshooting Guide

Error Indicators and Fault Solutions

Explains common indicators and messages, providing solutions for faults like high salt or no flow.